A new program for highly reproducible automatic evaluation of the substantia nigra from transcranial sonographic images
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F47813059%3A19240%2F13%3A%230004800" target="_blank" >RIV/47813059:19240/13:#0004800 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989592:15110/13:33149367 RIV/00843989:_____/14:E0104282
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A new program for highly reproducible automatic evaluation of the substantia nigra from transcranial sonographic images
Popis výsledku v původním jazyce
Aims: Recent studies report increased echogenicity of the substantia nigra (SN) in patients with Parkinson's disease (PD) using transcranial sonography (TCS). However, the main limitation to TCS is its dependence on the sonographer's experience. Experimental software for quantitative evaluation of the echogenic SN area was thus developed by us. The aim of this study was to test the reliability of the data using developed B-Mode Assist software in patients with parkinsonism and in healthy volunteers. Methods: The SN was imaged from the right temporal bone window in mesencephalic plane using TCS. DICOM images of SN were saved, converted into JPEG format, encoded and processed. Two observers performed 3 automatic evaluations of the SN area (measurements of SN area in each gray scale intensity inside the region of interest) by counting the standard deviation of all 6 measurements using developed software. The average value of all 3 measurements of each observer was used for computing Cohen
Název v anglickém jazyce
A new program for highly reproducible automatic evaluation of the substantia nigra from transcranial sonographic images
Popis výsledku anglicky
Aims: Recent studies report increased echogenicity of the substantia nigra (SN) in patients with Parkinson's disease (PD) using transcranial sonography (TCS). However, the main limitation to TCS is its dependence on the sonographer's experience. Experimental software for quantitative evaluation of the echogenic SN area was thus developed by us. The aim of this study was to test the reliability of the data using developed B-Mode Assist software in patients with parkinsonism and in healthy volunteers. Methods: The SN was imaged from the right temporal bone window in mesencephalic plane using TCS. DICOM images of SN were saved, converted into JPEG format, encoded and processed. Two observers performed 3 automatic evaluations of the SN area (measurements of SN area in each gray scale intensity inside the region of interest) by counting the standard deviation of all 6 measurements using developed software. The average value of all 3 measurements of each observer was used for computing Cohen
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers
ISSN
1213-8118
e-ISSN
—
Svazek periodika
157
Číslo periodika v rámci svazku
neuveden
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
1-7
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—