Ultrasound B-MODE image processing as a Matlab software tool and as an experimental solution on ARM platform
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F47813059%3A19240%2F15%3A%230005539" target="_blank" >RIV/47813059:19240/15:#0005539 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/login.jsp?tp=&arnumber=7313801&url=http%3A%2F%2Fieeexplore.ieee.org%2Fiel7%2F7299993%2F7313653%2F07313801.pdf%3Farnumber%3D7313801" target="_blank" >http://ieeexplore.ieee.org/xpl/login.jsp?tp=&arnumber=7313801&url=http%3A%2F%2Fieeexplore.ieee.org%2Fiel7%2F7299993%2F7313653%2F07313801.pdf%3Farnumber%3D7313801</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EUROCON.2015.7313801" target="_blank" >10.1109/EUROCON.2015.7313801</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ultrasound B-MODE image processing as a Matlab software tool and as an experimental solution on ARM platform
Popis výsledku v původním jazyce
The paper is focused on image processing of B-images from diagnostic ultrasound, their processing and analysis with own developed algorithm based on binary thresholding which is useful for images in grayscale such as B-images. The presented algorithm hasbeen created as MATLAB-based application and verified its function for 2 different structures displayed in midbrain ? substantia nigra and raphe nucleus. The processing and analysis is based on measuring of their echogenicity level from the principle ofB-MODE. The results also was verified and rated by an experienced sonographer. The second part is focused on implementation of the algorithm on embedded system ARM Cortex-M4 which allows to create an independent hardware computing unit connectable to anultrasound machine. Sonographers could evaluate pathological issues directly with no loading images to a computer. We selected ARM platform due to its performance, low consumption and hardware scalability. Communication from MATLAB is re
Název v anglickém jazyce
Ultrasound B-MODE image processing as a Matlab software tool and as an experimental solution on ARM platform
Popis výsledku anglicky
The paper is focused on image processing of B-images from diagnostic ultrasound, their processing and analysis with own developed algorithm based on binary thresholding which is useful for images in grayscale such as B-images. The presented algorithm hasbeen created as MATLAB-based application and verified its function for 2 different structures displayed in midbrain ? substantia nigra and raphe nucleus. The processing and analysis is based on measuring of their echogenicity level from the principle ofB-MODE. The results also was verified and rated by an experienced sonographer. The second part is focused on implementation of the algorithm on embedded system ARM Cortex-M4 which allows to create an independent hardware computing unit connectable to anultrasound machine. Sonographers could evaluate pathological issues directly with no loading images to a computer. We selected ARM platform due to its performance, low consumption and hardware scalability. Communication from MATLAB is re
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
IN - Informatika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0070" target="_blank" >ED1.1.00/02.0070: Centrum excelence IT4Innovations</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EUROCON 2015 - International Conference on Computer as a Tool (EUROCON), IEEE
ISBN
978-1-4799-8568-5
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
—
Místo konání akce
Salamanca, Spain
Datum konání akce
1. 1. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—