The forensic application of biomechanics deals with the decoding of relevant criminalistic information reflecting the functional and dynamic characteristic of the offender's or some other person's organism. Most frequently the attack is directed on the head of the victim. Important is if the attacked person died instantly or survived . It is important to determine and quantify the limit for possible survival after this cerebral mechanical loading of the victim's head structures. The experimental data are necessary to the assessment of the biomechanical model of the tolerance of organism to the dynamical loading. Up to now the best expression of the critical values is under "Wayne State Curve". The mentioned curve describes the situation of a direct hit(stroke) of the head against a flat blunt object, and vice versa. The mentioned curve may be expressed as the time integral of an algebraic function, of the acceleration a(t).
Název v anglickém jazyce
Biomechanical analysis of extreme dynamic loading on organism.
Popis výsledku anglicky
The forensic application of biomechanics deals with the decoding of relevant criminalistic information reflecting the functional and dynamic characteristic of the offender's or some other person's organism. Most frequently the attack is directed on the head of the victim. Important is if the attacked person died instantly or survived . It is important to determine and quantify the limit for possible survival after this cerebral mechanical loading of the victim's head structures. The experimental data are necessary to the assessment of the biomechanical model of the tolerance of organism to the dynamical loading. Up to now the best expression of the critical values is under "Wayne State Curve". The mentioned curve describes the situation of a direct hit(stroke) of the head against a flat blunt object, and vice versa. The mentioned curve may be expressed as the time integral of an algebraic function, of the acceleration a(t).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
AQ - Bezpečnost a ochrana zdraví, člověk – stroj
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Human biomechanice 2008 : sborník z konference.
ISBN
978-80-01-04163-5
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
Fakulta tělesné výchovy a sportu UK
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
1. 1. 2008
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—