Experimental and numerical study on pressure losses and pressure fluctuations in a valve assembly with three control valves in one chamber
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49193864%3A_____%2F25%3AN0000001" target="_blank" >RIV/49193864:_____/25:N0000001 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.euroturbo.eu/publications/proceedings-papers/ETC2025-130/" target="_blank" >https://www.euroturbo.eu/publications/proceedings-papers/ETC2025-130/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental and numerical study on pressure losses and pressure fluctuations in a valve assembly with three control valves in one chamber
Popis výsledku v původním jazyce
doi.org/10.29008/ETC2025-130 This paper presents a study of the flow field in an up-to-date model of a modern high-pressure valve assembly used for nozzle-governing turbines with outputs lower than 50 MW. This assembly consists of one stop valve and three control valves connected by the so-called lift bar. The study aims to evaluate and compare pressure losses and flow instabilities in each control valve. Numerical simulations have been carried out in the Doosan Skoda Power company using the Ansys CFX software tool to complement the results. Measurements have been carried out in the Aerodynamic laboratory of the Institute of Thermomechanics of the Czech Academy of Sciences, where an aerodynamic tunnel is installed. . The measurement results are compared with the numerical results in the form of pressure loss prediction. The measured pressure fluctuations are utilized to define a border, in terms of operating conditions, where the flow field starts to be unstable. Therefore, the areas of safety and dangerous operational reliability can be predicted.
Název v anglickém jazyce
Experimental and numerical study on pressure losses and pressure fluctuations in a valve assembly with three control valves in one chamber
Popis výsledku anglicky
doi.org/10.29008/ETC2025-130 This paper presents a study of the flow field in an up-to-date model of a modern high-pressure valve assembly used for nozzle-governing turbines with outputs lower than 50 MW. This assembly consists of one stop valve and three control valves connected by the so-called lift bar. The study aims to evaluate and compare pressure losses and flow instabilities in each control valve. Numerical simulations have been carried out in the Doosan Skoda Power company using the Ansys CFX software tool to complement the results. Measurements have been carried out in the Aerodynamic laboratory of the Institute of Thermomechanics of the Czech Academy of Sciences, where an aerodynamic tunnel is installed. . The measurement results are compared with the numerical results in the form of pressure loss prediction. The measured pressure fluctuations are utilized to define a border, in terms of operating conditions, where the flow field starts to be unstable. Therefore, the areas of safety and dangerous operational reliability can be predicted.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20303 - Thermodynamics
Návaznosti výsledku
Projekt
<a href="/cs/project/TN02000025" target="_blank" >TN02000025: Národní centrum pro energetiku II</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů