High pressure axial flow fans for modern coal power stations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49679155%3A_____%2F08%3A%230000002" target="_blank" >RIV/49679155:_____/08:#0000002 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High pressure axial flow fans for modern coal power stations
Popis výsledku v původním jazyce
Four variants of new high pressure axial flow fan stages were designed in AHT Energetika Ltd for power industry. They have hub/tip ratio value of 0.6. Design flow and pressure coefficients were in the range of 0.35 - 0.6 and 0.46-0.95.The aerodynamic loading of rotor and stator blade elements was high. Experimental verification of fan stage aerodynamic performance was carried out on test rig with external diameter of 600 mm. Several simple dependencies for the determination of the fan principal parameters were derived. Two one stage fan variants for modern coal fired power station blocks with the electrical output of 660 MW were designed. The application of new axial flow stages enabled the design of one stage fan with an external diameter of 4.5 m anda peripheral velocity of 177 m/s. Use of traditional stage design leads to more expensive two stage fan.
Název v anglickém jazyce
High pressure axial flow fans for modern coal power stations
Popis výsledku anglicky
Four variants of new high pressure axial flow fan stages were designed in AHT Energetika Ltd for power industry. They have hub/tip ratio value of 0.6. Design flow and pressure coefficients were in the range of 0.35 - 0.6 and 0.46-0.95.The aerodynamic loading of rotor and stator blade elements was high. Experimental verification of fan stage aerodynamic performance was carried out on test rig with external diameter of 600 mm. Several simple dependencies for the determination of the fan principal parameters were derived. Two one stage fan variants for modern coal fired power station blocks with the electrical output of 660 MW were designed. The application of new axial flow stages enabled the design of one stage fan with an external diameter of 4.5 m anda peripheral velocity of 177 m/s. Use of traditional stage design leads to more expensive two stage fan.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/2A-1TP1%2F052" target="_blank" >2A-1TP1/052: Ventilátory s progresivními parametry pro energetická a ekologická zařízení.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Tagungsband Teil2 , XL. Kraftwerktechnisches Kolloquium
ISBN
978-3-00-025948-7
ISSN
1863-5822
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
TU Dresden
Místo vydání
Dresden
Místo konání akce
Dresden
Datum konání akce
1. 1. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—