WWER Steam Generators
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23210%2F17%3A43931803" target="_blank" >RIV/49777513:23210/17:43931803 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/49777513:23510/17:43931803
Výsledek na webu
<a href="https://www.elsevier.com/books/steam-generators-for-nuclear-power-plants/riznic/978-0-08-100894-2" target="_blank" >https://www.elsevier.com/books/steam-generators-for-nuclear-power-plants/riznic/978-0-08-100894-2</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/B978-0-08-100894-2.00007-8" target="_blank" >10.1016/B978-0-08-100894-2.00007-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
WWER Steam Generators
Popis výsledku v původním jazyce
The basic feature of WWER steam generators are two vertical tube sheets (collectors) and horizontal heat exchange tube bundles. The tube bundle and the perforated part of collectors are above bottom of SG vessel where the sludge is settled. Evaporation surface is relatively large i.e. the steam mass flux is low and therefore only simple separation blinds (WWER 440) or perforated plate (WWER 1000) are sufficient for these steam generators. In comparison with vertical steam generators, this collectors-tube bundles configuration significantly changes the two-phase mixture circulation on the secondary side of steam generator. The distribution of impurities in steam generators, which determines the steam generators lifetime, depends on circulation and circulation depends on feedwater distribution and blowdown system. This chapter is focused on weak points of WWER steam generators and it is divided into following parts: 1. Brief description of WWER 440 and WWER 1000 steam generators. 2. Steam generator degradation 3. Steam generators modifications 4. Heat exchange tubes integrity
Název v anglickém jazyce
WWER Steam Generators
Popis výsledku anglicky
The basic feature of WWER steam generators are two vertical tube sheets (collectors) and horizontal heat exchange tube bundles. The tube bundle and the perforated part of collectors are above bottom of SG vessel where the sludge is settled. Evaporation surface is relatively large i.e. the steam mass flux is low and therefore only simple separation blinds (WWER 440) or perforated plate (WWER 1000) are sufficient for these steam generators. In comparison with vertical steam generators, this collectors-tube bundles configuration significantly changes the two-phase mixture circulation on the secondary side of steam generator. The distribution of impurities in steam generators, which determines the steam generators lifetime, depends on circulation and circulation depends on feedwater distribution and blowdown system. This chapter is focused on weak points of WWER steam generators and it is divided into following parts: 1. Brief description of WWER 440 and WWER 1000 steam generators. 2. Steam generator degradation 3. Steam generators modifications 4. Heat exchange tubes integrity
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Steam Generators for Nuclear Power Plants
ISBN
978-0-08-100894-2
Počet stran výsledku
18
Strana od-do
107-124
Počet stran knihy
578
Název nakladatele
Elsevier
Místo vydání
Amsterdam
Kód UT WoS kapitoly
—