REVERSE APPLICATION OF MSA TOOL FOR CMM STYLUS EVALUATION
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23210%2F19%3A43957936" target="_blank" >RIV/49777513:23210/19:43957936 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.2507/30th.daaam.proceedings.053" target="_blank" >http://dx.doi.org/10.2507/30th.daaam.proceedings.053</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2507/30th.daaam.proceedings.053" target="_blank" >10.2507/30th.daaam.proceedings.053</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
REVERSE APPLICATION OF MSA TOOL FOR CMM STYLUS EVALUATION
Popis výsledku v původním jazyce
In today's robust quality management systems, final inspection is a critical process that often determines the success of the entire production. For this reason, the most accurate measuring instruments available to the manufacturer are used in the final inspection and the measurements take place under controlled conditions of metrology laboratories. A very frequently used device, valued for its versatility and accuracy, is CMM. Modern CMM machines achieve high precision by the touch method below 1m and versatility achieved through a wide range of movements. The article describes an experiment during which a reverse application of the MSA method was performed to verify the effect of stylus diameter on variability in the measurement process. The results of an experiment carried out in an accredited metrology laboratory show a significant influence of this parameter on the overall measurement accurac
Název v anglickém jazyce
REVERSE APPLICATION OF MSA TOOL FOR CMM STYLUS EVALUATION
Popis výsledku anglicky
In today's robust quality management systems, final inspection is a critical process that often determines the success of the entire production. For this reason, the most accurate measuring instruments available to the manufacturer are used in the final inspection and the measurements take place under controlled conditions of metrology laboratories. A very frequently used device, valued for its versatility and accuracy, is CMM. Modern CMM machines achieve high precision by the touch method below 1m and versatility achieved through a wide range of movements. The article describes an experiment during which a reverse application of the MSA method was performed to verify the effect of stylus diameter on variability in the measurement process. The results of an experiment carried out in an accredited metrology laboratory show a significant influence of this parameter on the overall measurement accurac
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 30th International DAAAM Symposium ''Intelligent Manufacturing & Automation''
ISBN
978-3-902734-22-8
ISSN
1726-9679
e-ISSN
—
Počet stran výsledku
4
Strana od-do
390-393
Název nakladatele
DAAAM International Vienna
Místo vydání
Vídeň
Místo konání akce
Zadar, Croatia EU
Datum konání akce
23. 10. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—