Prediction of voltage dips in an electric power system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F01%3A00064634" target="_blank" >RIV/49777513:23220/01:00064634 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Prediction of voltage dips in an electric power system
Popis výsledku v původním jazyce
Voltage dips (sags), mainly caused by remote short circuits, are generally considered the serious power quality problem. Their effect on an operation of sensitive equipment is the same like the effect of short supply interruptions. The knowledge about occurrence of a voltage dips in a network as a function of their magnitude and duration can be obtained through the use of power quality monitors or by means of prediction methods. This paper compares advantages and disadvantages of the voltage dips monitoring and the prediction methods, and limitations of their practical using for the prediction of the number of voltage dips in the power system. The principles of two prediction methods (the method of fault positions and the method of critical distances)are mentioned. The method of fault positions is applied to the real 110 kV grid. The accuracy of the prediction method is evaluated on the basis of the comparison with the outcome of the voltage dip monitoring.
Název v anglickém jazyce
Prediction of voltage dips in an electric power system
Popis výsledku anglicky
Voltage dips (sags), mainly caused by remote short circuits, are generally considered the serious power quality problem. Their effect on an operation of sensitive equipment is the same like the effect of short supply interruptions. The knowledge about occurrence of a voltage dips in a network as a function of their magnitude and duration can be obtained through the use of power quality monitors or by means of prediction methods. This paper compares advantages and disadvantages of the voltage dips monitoring and the prediction methods, and limitations of their practical using for the prediction of the number of voltage dips in the power system. The principles of two prediction methods (the method of fault positions and the method of critical distances)are mentioned. The method of fault positions is applied to the real 110 kV grid. The accuracy of the prediction method is evaluated on the basis of the comparison with the outcome of the voltage dip monitoring.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Prediction of voltage dips in an electric power system
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Neuveden
Datum konání akce
1. 1. 2001
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—