Calculation of voltage dips in a 110 kV network
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F02%3A00072606" target="_blank" >RIV/49777513:23220/02:00072606 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calculation of voltage dips in a 110 kV network
Popis výsledku v původním jazyce
The paper deals with the calculation of number and severity of voltage dips and the comparison of results with outcome of voltage dip monitoring. Method of fault positions is used. The remaining voltage is calculated for faults in each fault position. The computation was performed for all kind of faults and different failure rates of particular lines. Knowing the network parameters and the failure statistics of the network, the number of dips and distribution of remaining voltages can be estimated. Themethod of fault positions is applied to the real 110 kV grid. The expected number of dips and distribution of remaining voltage in the substation, and exposed area for this substation are calculated. The results are compared with the outcome of the voltage dip monitoring. The comparison shows a good correspondence in general.
Název v anglickém jazyce
Calculation of voltage dips in a 110 kV network
Popis výsledku anglicky
The paper deals with the calculation of number and severity of voltage dips and the comparison of results with outcome of voltage dip monitoring. Method of fault positions is used. The remaining voltage is calculated for faults in each fault position. The computation was performed for all kind of faults and different failure rates of particular lines. Knowing the network parameters and the failure statistics of the network, the number of dips and distribution of remaining voltages can be estimated. Themethod of fault positions is applied to the real 110 kV grid. The expected number of dips and distribution of remaining voltage in the substation, and exposed area for this substation are calculated. The results are compared with the outcome of the voltage dip monitoring. The comparison shows a good correspondence in general.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F02%2F0949" target="_blank" >GA102/02/0949: Analýza a simulace nespecifických poruch v elektrických sítích a predikční řízení dodávek elektrické energie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Calculation of voltage dips in a 110 kV network
ISBN
8001026140
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
89
Název nakladatele
ČVUT
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
1. 1. 2002
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—