Stárnutí minerálních a syntetických izolačních olejů z pohledu strukturálních analýz
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F08%3A00500446" target="_blank" >RIV/49777513:23220/08:00500446 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Aging of Petroleum and Synthetic Based Insulation Oils from the View of Structural Analyses
Popis výsledku v původním jazyce
Insulating system of power transformers is mostly composed of two basic components: insulation oil and cellulose paper (oil-paper system). Aging of these components can endanger the failure free operation of the transformers. The main objective of the paper was to analyze the aging process of liquid part of oil-paper insulation system by selected structural analyses. Three petroleum and three synthetic based insulation oils were chosen for the purpose of this experiment. The commercially available cellulose paper formed the solid part of the insulation. All insulation systems were exposed to accelerated thermal aging at increased temperature of 90 °C for the time range of 50-3000 hours. The degradation of oils inner structure was analyzed by Fourier Transform Infrared Spectroscopy and Thermogravimetry and Derivative Thermogravimetry were applied.
Název v anglickém jazyce
Aging of Petroleum and Synthetic Based Insulation Oils from the View of Structural Analyses
Popis výsledku anglicky
Insulating system of power transformers is mostly composed of two basic components: insulation oil and cellulose paper (oil-paper system). Aging of these components can endanger the failure free operation of the transformers. The main objective of the paper was to analyze the aging process of liquid part of oil-paper insulation system by selected structural analyses. Three petroleum and three synthetic based insulation oils were chosen for the purpose of this experiment. The commercially available cellulose paper formed the solid part of the insulation. All insulation systems were exposed to accelerated thermal aging at increased temperature of 90 °C for the time range of 50-3000 hours. The degradation of oils inner structure was analyzed by Fourier Transform Infrared Spectroscopy and Thermogravimetry and Derivative Thermogravimetry were applied.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
16th IEEE International Conference on Dielectric Liquids ICDL 2008
ISBN
978-1-4244-1586-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Poitiers
Datum konání akce
3. 7. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—