The Possibilities of Mathematic Simulation Using for Examination of RES Connecting System Behaviour
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F08%3A00501067" target="_blank" >RIV/49777513:23220/08:00501067 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Possibilities of Mathematic Simulation Using for Examination of RES Connecting System Behaviour
Popis výsledku v původním jazyce
Distribution power systems of MVwere designed from the historical point only for the electric power supply to end users, it means the one-way electric power flow from the supply substation to the consumers.If we connect to this system a distributed electric energy source, the voltage rates along the power lines are changing in dependence on the active and reactive power of the inserted source and voltage level keeping in the specified rates along the whole line should be problematic under the classic voltage control way. Before the connection realisation it is necessary to make computations which prove the performance of the requested conditions. For the solving of this the electric power system model, which respects the grid configuration together with the parameters of its parts, the point of the generator connection and its parameters, can be used.
Název v anglickém jazyce
The Possibilities of Mathematic Simulation Using for Examination of RES Connecting System Behaviour
Popis výsledku anglicky
Distribution power systems of MVwere designed from the historical point only for the electric power supply to end users, it means the one-way electric power flow from the supply substation to the consumers.If we connect to this system a distributed electric energy source, the voltage rates along the power lines are changing in dependence on the active and reactive power of the inserted source and voltage level keeping in the specified rates along the whole line should be problematic under the classic voltage control way. Before the connection realisation it is necessary to make computations which prove the performance of the requested conditions. For the solving of this the electric power system model, which respects the grid configuration together with the parameters of its parts, the point of the generator connection and its parameters, can be used.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F06%2F0132" target="_blank" >GA102/06/0132: Obnovitelné zdroje energie a jejich začleňování do energetických systémů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2008 IEEE/PES Transmission and Distribution Conference and Exposition
ISBN
978-1-4244-1903-6
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Chicago
Datum konání akce
24. 4. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000258172300111