Partial discharges of thermally and electrically aged insulation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F09%3A00501809" target="_blank" >RIV/49777513:23220/09:00501809 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Partial discharges of thermally and electrically aged insulation
Popis výsledku v původním jazyce
The working life of electrical machines is primary affected by the insulation system quality. Diagnostics methods help to understand the momentary state of insulation and to avoid the possible damage or electrical breakdown of machines through the repairor insulation rewinding. Partial discharges testing belongs to one of the high applicable test method of insulating materials within electrical machines. The described experiment consists of laboratory thermal and electrical aging of main wall insulation and consequently testing of partial discharges. The test material consists of resin rich mica composites based on glass fabric and epoxy resin. The flat specimens of insulation were cured and thermally and electrically aged and the partial discharges were measured accordingly. The thermal aging was performed at four different temperatures (170, 175, 180, 186 °C) at different times. The electrical aging was completed at two different voltage levels (10, 12 kV) at different times. The fl
Název v anglickém jazyce
Partial discharges of thermally and electrically aged insulation
Popis výsledku anglicky
The working life of electrical machines is primary affected by the insulation system quality. Diagnostics methods help to understand the momentary state of insulation and to avoid the possible damage or electrical breakdown of machines through the repairor insulation rewinding. Partial discharges testing belongs to one of the high applicable test method of insulating materials within electrical machines. The described experiment consists of laboratory thermal and electrical aging of main wall insulation and consequently testing of partial discharges. The test material consists of resin rich mica composites based on glass fabric and epoxy resin. The flat specimens of insulation were cured and thermally and electrically aged and the partial discharges were measured accordingly. The thermal aging was performed at four different temperatures (170, 175, 180, 186 °C) at different times. The electrical aging was completed at two different voltage levels (10, 12 kV) at different times. The fl
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2009 IEEE CEIDP
ISBN
978-1-4244-4557-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Virginia Beach
Datum konání akce
1. 1. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000279096900012