The enormous expansion of technologies of the acquisition of electrical energy, which we witness at the present time, is based not only on the process of its generation. If electrical energy is to be used effectively, the generation of electrical energyhas to be closely incorporated into the quality and functionality of the transmission and distribution system. The increase of demands on the reliability and quality of the operation of technical equipment generally and the power equipment especially isconnected with this. High demands on the design and factory price of most of this equipment led to the development of various branches of diagnostics, which in a way makes it possible to deal with the problems of reliability and economy of the operation.At present there are growing demands on online monitoring of the operating condition of the most important component of the power unit, namely by such equipment as for example the nuclear power plant. The transformer as one of the key co
Název v anglickém jazyce
Acoustic Method in Diagnostics of Transformer Insulating
Popis výsledku anglicky
The enormous expansion of technologies of the acquisition of electrical energy, which we witness at the present time, is based not only on the process of its generation. If electrical energy is to be used effectively, the generation of electrical energyhas to be closely incorporated into the quality and functionality of the transmission and distribution system. The increase of demands on the reliability and quality of the operation of technical equipment generally and the power equipment especially isconnected with this. High demands on the design and factory price of most of this equipment led to the development of various branches of diagnostics, which in a way makes it possible to deal with the problems of reliability and economy of the operation.At present there are growing demands on online monitoring of the operating condition of the most important component of the power unit, namely by such equipment as for example the nuclear power plant. The transformer as one of the key co
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2010 IEEE International Conference on Solid Dielectrics
ISBN
978-1-4244-7944-3
ISSN
—
e-ISSN
—
Počet stran výsledku
833
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Potsdam, Germany
Datum konání akce
1. 1. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—