Single-Phase Active Current-Source Rectifier Operated with Power Factor and Distortion Power Factor Control
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F11%3A43895774" target="_blank" >RIV/49777513:23220/11:43895774 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/PEDS.2011.6147392" target="_blank" >http://dx.doi.org/10.1109/PEDS.2011.6147392</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/PEDS.2011.6147392" target="_blank" >10.1109/PEDS.2011.6147392</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Single-Phase Active Current-Source Rectifier Operated with Power Factor and Distortion Power Factor Control
Popis výsledku v původním jazyce
In this paper, new control strategy of single phase active current-source rectifier (ACSR) able to control Power Factor (PF) as well as Distortion Power Factor (DPF) will be presented. The PF part is based on direct cos ? control with phase shift controller, the DPF part provides active mitigation of selected low-frequency harmonics in trolley-wire current using resonant (R) controllers. The ACSR developed within the research into a new generation of main traction converters employing medium-frequency transformer dedicated for suburban units operating on both ac electrification systems of 25kV/50 Hz and 15kV/16,7 Hz. Proper function of proposed control strategy with a new compensative principle has been verified by simulations and large experimental study made on designed small-scale prototype of ACSR of rated power of 7kVA.
Název v anglickém jazyce
Single-Phase Active Current-Source Rectifier Operated with Power Factor and Distortion Power Factor Control
Popis výsledku anglicky
In this paper, new control strategy of single phase active current-source rectifier (ACSR) able to control Power Factor (PF) as well as Distortion Power Factor (DPF) will be presented. The PF part is based on direct cos ? control with phase shift controller, the DPF part provides active mitigation of selected low-frequency harmonics in trolley-wire current using resonant (R) controllers. The ACSR developed within the research into a new generation of main traction converters employing medium-frequency transformer dedicated for suburban units operating on both ac electrification systems of 25kV/50 Hz and 15kV/16,7 Hz. Proper function of proposed control strategy with a new compensative principle has been verified by simulations and large experimental study made on designed small-scale prototype of ACSR of rated power of 7kVA.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE PEDS 2011
ISBN
978-1-4577-0000-2
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1068-1073
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Singapur
Datum konání akce
5. 12. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—