Variable Speed Pumping in Thermal and Nuclear Power Plants: Frequency Converter versus Hydrodynamic Coupling
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F11%3A43898660" target="_blank" >RIV/49777513:23220/11:43898660 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/PEDS.2011.6147251" target="_blank" >http://dx.doi.org/10.1109/PEDS.2011.6147251</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/PEDS.2011.6147251" target="_blank" >10.1109/PEDS.2011.6147251</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Variable Speed Pumping in Thermal and Nuclear Power Plants: Frequency Converter versus Hydrodynamic Coupling
Popis výsledku v původním jazyce
In this paper, a comprehensive case study analysis of flow control methods and appropriate technical implementations for high-power pump systems employed in thermal and nuclear power plants or heating plants will be presented. The main attention is focused on a comparison of two advanced variable speed control strategies employing VSD with frequency converter and VSD with hydrodynamic coupling. In addition, we have included comparison with conventional flow control methods like throttling, bypass and on-of control. The calculations were performed in the software, which we have developed for design, optimization and sophisticated comparison of these drives. It is presented the methodology and developed models for evaluation of the whole drive chain fromhydraulic system over pump, drive components and power supply.
Název v anglickém jazyce
Variable Speed Pumping in Thermal and Nuclear Power Plants: Frequency Converter versus Hydrodynamic Coupling
Popis výsledku anglicky
In this paper, a comprehensive case study analysis of flow control methods and appropriate technical implementations for high-power pump systems employed in thermal and nuclear power plants or heating plants will be presented. The main attention is focused on a comparison of two advanced variable speed control strategies employing VSD with frequency converter and VSD with hydrodynamic coupling. In addition, we have included comparison with conventional flow control methods like throttling, bypass and on-of control. The calculations were performed in the software, which we have developed for design, optimization and sophisticated comparison of these drives. It is presented the methodology and developed models for evaluation of the whole drive chain fromhydraulic system over pump, drive components and power supply.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE PEDS 2011
ISBN
978-1-4577-0000-2
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Singapore
Datum konání akce
5. 12. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—