Cole-Cole diagram as Diagnostic Tool for Dielectric Liquids
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F11%3A43907983" target="_blank" >RIV/49777513:23220/11:43907983 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/ICDL.2011.6015448" target="_blank" >http://dx.doi.org/10.1109/ICDL.2011.6015448</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICDL.2011.6015448" target="_blank" >10.1109/ICDL.2011.6015448</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Cole-Cole diagram as Diagnostic Tool for Dielectric Liquids
Popis výsledku v původním jazyce
Dielectric subsystems have an important influence on reliability, lifetime and power of electrical equipments. Study of dielectric parameters and their changes due to degradation mechanisms provide important information about the equipments. Paper dealswith oil-paper systems and their thermal degradation. These systems are used for example in transformer, capacitors and bushings. Thermal degradation causes increasing of moisture content thus number of polar particles. Therefore the main idea of this paper is diagnostic of oil-paper insulation based on a method of polarization measurement. One of the methods is Cole-Cole diagram or its modification e.g. Davidson, Havriliak-Negami. The next aim of the paper is measurement of the system parameters (Complex permittivity, Viscosity, Acid value, Resistivity, Polarization index and Dissipation factor) and their changes due to thermal degradation. In experiments are used a normal and an environmental friendly fluid.
Název v anglickém jazyce
Cole-Cole diagram as Diagnostic Tool for Dielectric Liquids
Popis výsledku anglicky
Dielectric subsystems have an important influence on reliability, lifetime and power of electrical equipments. Study of dielectric parameters and their changes due to degradation mechanisms provide important information about the equipments. Paper dealswith oil-paper systems and their thermal degradation. These systems are used for example in transformer, capacitors and bushings. Thermal degradation causes increasing of moisture content thus number of polar particles. Therefore the main idea of this paper is diagnostic of oil-paper insulation based on a method of polarization measurement. One of the methods is Cole-Cole diagram or its modification e.g. Davidson, Havriliak-Negami. The next aim of the paper is measurement of the system parameters (Complex permittivity, Viscosity, Acid value, Resistivity, Polarization index and Dissipation factor) and their changes due to thermal degradation. In experiments are used a normal and an environmental friendly fluid.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2011 IEEE International Conference on Dielectric Liquids
ISBN
978-1-4244-7355-7
ISSN
2153-3725
e-ISSN
—
Počet stran výsledku
4
Strana od-do
120-124
Název nakladatele
SINTEF Energi AS
Místo vydání
Trondheim
Místo konání akce
Trondheim
Datum konání akce
26. 6. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000295317700048