Popis výsledku v původním jazyce
Proton Exchange Membrane (PEM) fuel cells are currently seen as the most suitable choice for implementation into daily-use applications. However, the PEM technology does not yet fulfil all the necessary requirements that the mass-market demands and proper strides toward elimination of remaining issues have to be taken. Hence, in this paper, the focus is made on water management faults, i.e. flooding and drying. More precisely, it deals with detection of them with the use of Electrochemical Impedance Spectroscopy (EIS). The EIS was successfully applied as a diagnostic tool to a fuel cell stack consisted of 80 cells without usage of any special purpose measurement equipment, where, in addition to the stack current, only voltage of the complete stack wasmeasured. The paper describes the adjustments that were made on the EIS to make it capable of handling the diagnostics of fuel cell stacks. The results of the experimental study show that the approach is successful in detecting the floodi
Název v anglickém jazyce
Detection of Flooding and Drying inside a PEM Fuel Cell Stack
Popis výsledku anglicky
Proton Exchange Membrane (PEM) fuel cells are currently seen as the most suitable choice for implementation into daily-use applications. However, the PEM technology does not yet fulfil all the necessary requirements that the mass-market demands and proper strides toward elimination of remaining issues have to be taken. Hence, in this paper, the focus is made on water management faults, i.e. flooding and drying. More precisely, it deals with detection of them with the use of Electrochemical Impedance Spectroscopy (EIS). The EIS was successfully applied as a diagnostic tool to a fuel cell stack consisted of 80 cells without usage of any special purpose measurement equipment, where, in addition to the stack current, only voltage of the complete stack wasmeasured. The paper describes the adjustments that were made on the EIS to make it capable of handling the diagnostics of fuel cell stacks. The results of the experimental study show that the approach is successful in detecting the floodi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0013" target="_blank" >EE2.3.30.0013: Excelence lidských zdrojů jako zdroj konkurenceschopnosti</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Strojniski vestnik - Journal of Mechanical Engineering
ISSN
0039-2480
e-ISSN
—
Svazek periodika
59
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
SI - Slovinská republika
Počet stran výsledku
9
Strana od-do
56-64
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—