A comparative study of dielectric, mechanical and structural properties of fire-protective insulation based on XLPE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F13%3A43918747" target="_blank" >RIV/49777513:23220/13:43918747 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A comparative study of dielectric, mechanical and structural properties of fire-protective insulation based on XLPE
Popis výsledku v původním jazyce
Paper deals with comparing of dielectric, mechanical and structural properties of primary cable insulation based on cross-linked low density polyethylene (XLPE) with different level of cross-linking. Testing material was divided into four groups according to time of exposition to low pressure steam, which initiates cross-linking reaction. The measurement of the degree of cross-linking by chemical extraction in xylene solution at 140 °C according to ASTM D2795 ? 11 followed. Dielectric properties (polarization index, volume resistivity) of the individual samples were then measured according to standards. Dielectric properties were compared with results of tensile strength test at various temperatures (50 °C, 55 °C, 60 °C) measured by dynamic mechanicalanalysis. The degree of cross-linking represented by the gel content positively influences the tensile strength, the volume resistivity and the change of structural behaviour of the material by differential scanning calorimetry was also o
Název v anglickém jazyce
A comparative study of dielectric, mechanical and structural properties of fire-protective insulation based on XLPE
Popis výsledku anglicky
Paper deals with comparing of dielectric, mechanical and structural properties of primary cable insulation based on cross-linked low density polyethylene (XLPE) with different level of cross-linking. Testing material was divided into four groups according to time of exposition to low pressure steam, which initiates cross-linking reaction. The measurement of the degree of cross-linking by chemical extraction in xylene solution at 140 °C according to ASTM D2795 ? 11 followed. Dielectric properties (polarization index, volume resistivity) of the individual samples were then measured according to standards. Dielectric properties were compared with results of tensile strength test at various temperatures (50 °C, 55 °C, 60 °C) measured by dynamic mechanicalanalysis. The degree of cross-linking represented by the gel content positively influences the tensile strength, the volume resistivity and the change of structural behaviour of the material by differential scanning calorimetry was also o
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
11th International Conference on Solid Dielectrics (ICSD)
ISBN
978-1-4799-0807-3
ISSN
1553-5282
e-ISSN
—
Počet stran výsledku
4
Strana od-do
674-677
Název nakladatele
The Institute of Electrical and Electronics Engineers, Inc.
Místo vydání
Piscataway
Místo konání akce
Bologna
Datum konání akce
30. 6. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—