Electronic System for Measuring and Optimization of Pacemaker Pulses
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F13%3A43918812" target="_blank" >RIV/49777513:23220/13:43918812 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/13:10139675 RIV/00669806:_____/13:10139675
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electronic System for Measuring and Optimization of Pacemaker Pulses
Popis výsledku v původním jazyce
A pacemaker is a small electronic device implanted under the skin near the collarbone. Pacemakers monitor the heart?s electrical activity. If the heart is beating too slowly or pausing too long between beats, the pacemaker will provide electrical impulses that stimulate the heart to beat. The pacemaker itself consists of a small box (the pulse generator) and one to three leads that are placed in the heart. This paper is devoted to electronic evaluating system which enables to find (in coordination withphysician) an optimal pacemaker electrical impulses, e.g. pulse width, amplitude, delay and lead (or leads) position in heart to reducing the delivered energy. Inputs of electronic evaluating system are taken from ECG (electro cardio graph) and Finapres(system for continuous measuring of blood pressure). Results will be helpful for prolonging battery longevity and reducing the stimuli pain on patients with implantable medical devices. There are present results of different approach base
Název v anglickém jazyce
Electronic System for Measuring and Optimization of Pacemaker Pulses
Popis výsledku anglicky
A pacemaker is a small electronic device implanted under the skin near the collarbone. Pacemakers monitor the heart?s electrical activity. If the heart is beating too slowly or pausing too long between beats, the pacemaker will provide electrical impulses that stimulate the heart to beat. The pacemaker itself consists of a small box (the pulse generator) and one to three leads that are placed in the heart. This paper is devoted to electronic evaluating system which enables to find (in coordination withphysician) an optimal pacemaker electrical impulses, e.g. pulse width, amplitude, delay and lead (or leads) position in heart to reducing the delivered energy. Inputs of electronic evaluating system are taken from ECG (electro cardio graph) and Finapres(system for continuous measuring of blood pressure). Results will be helpful for prolonging battery longevity and reducing the stimuli pain on patients with implantable medical devices. There are present results of different approach base
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
RECENT ADVANCES in TELECOMMUNICATIONS and CIRCUIT DESIGN
ISBN
978-960-474-310-0
ISSN
1790-5117
e-ISSN
—
Počet stran výsledku
7
Strana od-do
42-48
Název nakladatele
WSEAS Press
Místo vydání
Athens
Místo konání akce
Rhodos
Datum konání akce
16. 7. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—