The partial discharge measurement is well introduced for quality and diagnostic testing of important asset components as large generators, rotating machines etc. Usually the measurement procedure is given by standards as IEC 60270, whereby the results are evaluated by measured magnitude of apparent charge QIEC. For measuring of this parameter QIEC some requirements of the measuring system must be fulfilled. In previous papers was shown that the magnitude of QIEC doesn't represent the pd behaviour in every circumstances depending on the type of discharge, pd activity, number of pd sources etc. In this paper is discussed the adequate problem to estimate the partial discharge (PD) behaviour of typical stator bar insulation. The investigations were performed using stator bar models based on mica insulation and epoxy resin with slot and end bar corona protection. For estimation of the PD behaviour the standardized parameter QIEC and derived quantities as repetition rate, PD current recommen
Název v anglickém jazyce
Partial Discharge Measurement on Stator Bar Insulation
Popis výsledku anglicky
The partial discharge measurement is well introduced for quality and diagnostic testing of important asset components as large generators, rotating machines etc. Usually the measurement procedure is given by standards as IEC 60270, whereby the results are evaluated by measured magnitude of apparent charge QIEC. For measuring of this parameter QIEC some requirements of the measuring system must be fulfilled. In previous papers was shown that the magnitude of QIEC doesn't represent the pd behaviour in every circumstances depending on the type of discharge, pd activity, number of pd sources etc. In this paper is discussed the adequate problem to estimate the partial discharge (PD) behaviour of typical stator bar insulation. The investigations were performed using stator bar models based on mica insulation and epoxy resin with slot and end bar corona protection. For estimation of the PD behaviour the standardized parameter QIEC and derived quantities as repetition rate, PD current recommen
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ISH 2013 : proceedings : 18th International Symposium on High Voltage Engineering
ISBN
978-89-86510-18-8
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1929-1934
Název nakladatele
Hanyang University
Místo vydání
Seoul
Místo konání akce
Seoul, Korea
Datum konání akce
25. 8. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—