Comparison of accuracy of precision LCR meter during dielectric properties measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F13%3A43919035" target="_blank" >RIV/49777513:23220/13:43919035 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of accuracy of precision LCR meter during dielectric properties measurement
Popis výsledku v původním jazyce
The paper deals with the accuracy of measurement of precision LCR meter. Dielectric spectroscopy was used for evaluation of this test. The main aim of the paper is to compare the accuracy of measurement with measuring voltage of 1 V and 5 V in the frequency range from 200 Hz to 2 MHz. Two types of electrical insulating materials commonly used in many applications in high voltage engineering as a part of insulation system of large rotating machines (turbo or hydro generators) were used for this measurement. Expressive beta relaxation in measured dielectric spectra has been recorded and the accuracy of the measurement of the measured dielectric properties for used materials was compared for both measuring voltages.
Název v anglickém jazyce
Comparison of accuracy of precision LCR meter during dielectric properties measurement
Popis výsledku anglicky
The paper deals with the accuracy of measurement of precision LCR meter. Dielectric spectroscopy was used for evaluation of this test. The main aim of the paper is to compare the accuracy of measurement with measuring voltage of 1 V and 5 V in the frequency range from 200 Hz to 2 MHz. Two types of electrical insulating materials commonly used in many applications in high voltage engineering as a part of insulation system of large rotating machines (turbo or hydro generators) were used for this measurement. Expressive beta relaxation in measured dielectric spectra has been recorded and the accuracy of the measurement of the measured dielectric properties for used materials was compared for both measuring voltages.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International conference Diagnostika '13 Conference on Diagnostics in Electrical Engineering CDEE 2013
ISBN
978-80-261-0210-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
41-44
Název nakladatele
University of West Bohemia
Místo vydání
Pilsen
Místo konání akce
Plzeň
Datum konání akce
2. 9. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—