Comparison of temperature limits of cable sheaths measured by dynamic thermo mechanical analysis
Popis výsledku v původním jazyce
It is necessary to know temperature endurance of materials for using cable sheaths. Increasing temperature leads to softening of thermoplastics or even up to irreversible deformation of the shape and vice versa, decreasing temperature leads to gradual embrittlement and can cause the rupture of the material. The aim of the paper is to compare mechanical properties of sheathing materials used for cables during a broad temperature interval and recommend the right selection of material used for various applications. The paper is focused on a comparison of thermo-mechanical properties of six plastic insulation materials used for different cable sheaths made from: Polyurethane, Polyvinylchloride, Silicone rubber compound, Flexible elastomer based compound crosslinkable by exposure to moisture, Thermoplastic halogen-free flame-retardant (and low smoke emission) compound and Silane crosslinkable low-smoke low-toxicity halogen-free flame-retardant compound.
Název v anglickém jazyce
Comparison of temperature limits of cable sheaths measured by dynamic thermo mechanical analysis
Popis výsledku anglicky
It is necessary to know temperature endurance of materials for using cable sheaths. Increasing temperature leads to softening of thermoplastics or even up to irreversible deformation of the shape and vice versa, decreasing temperature leads to gradual embrittlement and can cause the rupture of the material. The aim of the paper is to compare mechanical properties of sheathing materials used for cables during a broad temperature interval and recommend the right selection of material used for various applications. The paper is focused on a comparison of thermo-mechanical properties of six plastic insulation materials used for different cable sheaths made from: Polyurethane, Polyvinylchloride, Silicone rubber compound, Flexible elastomer based compound crosslinkable by exposure to moisture, Thermoplastic halogen-free flame-retardant (and low smoke emission) compound and Silane crosslinkable low-smoke low-toxicity halogen-free flame-retardant compound.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International conference Diagnostika '13 Conference on Diagnostics in Electrical Engineering CDEE 2013
ISBN
978-80-261-0210-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
66-69