Electric drive with voltage-fed inverter with regard to influence of voltage sag
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F14%3A43923614" target="_blank" >RIV/49777513:23220/14:43923614 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electric drive with voltage-fed inverter with regard to influence of voltage sag
Popis výsledku v původním jazyce
This paper solves problematic of immunity of electric drive from the voltage sags on the power supply. Typical modern electric drive consist of the induction machine (or synchronous machine) supplied from indirect frequency converter with voltage-fed inverter and with non-controlled rectifier (or other - more complicated type of input side of this frequency converter). For this configuration are compared some variants how to achieve high immunity from the voltage sags. There are reflected opportune control algorithms (for induction machine etc.) for the quickly to change of working regime from full load in regime "drive" to "no-load" regime (to achieve for approximately constant value of voltage in capacitance in DC-link) and opportune control algorithms for quickly to return to original working regime after the regeneration of energy supply. There are also referenced the variants of adaptation of power circuits for to achieve a higher of immunity from the voltage sags. Special attenti
Název v anglickém jazyce
Electric drive with voltage-fed inverter with regard to influence of voltage sag
Popis výsledku anglicky
This paper solves problematic of immunity of electric drive from the voltage sags on the power supply. Typical modern electric drive consist of the induction machine (or synchronous machine) supplied from indirect frequency converter with voltage-fed inverter and with non-controlled rectifier (or other - more complicated type of input side of this frequency converter). For this configuration are compared some variants how to achieve high immunity from the voltage sags. There are reflected opportune control algorithms (for induction machine etc.) for the quickly to change of working regime from full load in regime "drive" to "no-load" regime (to achieve for approximately constant value of voltage in capacitance in DC-link) and opportune control algorithms for quickly to return to original working regime after the regeneration of energy supply. There are also referenced the variants of adaptation of power circuits for to achieve a higher of immunity from the voltage sags. Special attenti
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 16th International Conference on Mechatronics : Mechatronika 2014
ISBN
978-80-214-4816-2
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
666-671
Název nakladatele
Brno University of technology. Faculty of Mechanical Engineering
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
3. 12. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—