Space vector modulated four-quadrant active current-source rectifier with DFT based power factor control for DC motor drive
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F14%3A43928505" target="_blank" >RIV/49777513:23220/14:43928505 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7048748" target="_blank" >http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7048748</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/IECON.2014.7048748" target="_blank" >10.1109/IECON.2014.7048748</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Space vector modulated four-quadrant active current-source rectifier with DFT based power factor control for DC motor drive
Popis výsledku v původním jazyce
In high-power applications, current-source rectifiers are still popular due to their simple topology, robustness and nearly sinusoidal grid current. They can be also operated with unity or variable power factor. In this way, the rectifier can serve as apower factor compensator. Beside this, they directly control load current which makes them sufficient for direct supply of DC motor. However, the significant disadvantage of the common CSR topology is that they are not able to change load current direction - they operate only in two quadrants. In this paper, three phase space vector modulated four quadrant active current-source rectifier with DFT based power factor control for dc motor drive is introduced. Developed control algorithm is widely describedand its behavior verified by simulation study.
Název v anglickém jazyce
Space vector modulated four-quadrant active current-source rectifier with DFT based power factor control for DC motor drive
Popis výsledku anglicky
In high-power applications, current-source rectifiers are still popular due to their simple topology, robustness and nearly sinusoidal grid current. They can be also operated with unity or variable power factor. In this way, the rectifier can serve as apower factor compensator. Beside this, they directly control load current which makes them sufficient for direct supply of DC motor. However, the significant disadvantage of the common CSR topology is that they are not able to change load current direction - they operate only in two quadrants. In this paper, three phase space vector modulated four quadrant active current-source rectifier with DFT based power factor control for dc motor drive is introduced. Developed control algorithm is widely describedand its behavior verified by simulation study.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of IECON 2014 : 40th Annual Conference of the IEEE Industrial Electronics Society
ISBN
978-1-4799-4032-5
ISSN
1553-572X
e-ISSN
—
Počet stran výsledku
7
Strana od-do
1813-1819
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Dallas, USA
Datum konání akce
29. 10. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—