Optimalization of the measurement system for determination of the diffusion and reflection coefficients
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F15%3A43925498" target="_blank" >RIV/49777513:23220/15:43925498 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimalization of the measurement system for determination of the diffusion and reflection coefficients
Popis výsledku v původním jazyce
This paper focuses on a new design of the measurement system for the characterization of reflective materials. The main aim of this work was effectively and reproducibly measure the diffusion and reflection coefficient. Presented measurement system allows to provide the multichannel synchronization record from 47 microphones in real-time. The measurement system consists of the microphone frame, connection cables and electronic devices (for amplifying, converting, processing of the signals etc.). The microphones are distributed uniformly in the frame with the shape of the semicircle with the radius of 5m. The fixed microphone frame ensures the producibility of each measurement. The frame is multifunctional: (1) mechanical protection, (2) electrical connection and (3) it ensures the first stage of amplifier and it also provides the power supply for the microphones. The frame can be also decomposed into smaller parts for easy transport. Becasuse of the very low value of the noise backgrou
Název v anglickém jazyce
Optimalization of the measurement system for determination of the diffusion and reflection coefficients
Popis výsledku anglicky
This paper focuses on a new design of the measurement system for the characterization of reflective materials. The main aim of this work was effectively and reproducibly measure the diffusion and reflection coefficient. Presented measurement system allows to provide the multichannel synchronization record from 47 microphones in real-time. The measurement system consists of the microphone frame, connection cables and electronic devices (for amplifying, converting, processing of the signals etc.). The microphones are distributed uniformly in the frame with the shape of the semicircle with the radius of 5m. The fixed microphone frame ensures the producibility of each measurement. The frame is multifunctional: (1) mechanical protection, (2) electrical connection and (3) it ensures the first stage of amplifier and it also provides the power supply for the microphones. The frame can be also decomposed into smaller parts for easy transport. Becasuse of the very low value of the noise backgrou
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BI - Akustika a kmity
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FR-TI4%2F569" target="_blank" >FR-TI4/569: *Vývoj akustických difuzorů nové generace a jejich modelování</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
10th European Congress and Exposition on Noise Control Engineering (EuroNoise 2015) - Proceedings
ISBN
—
ISSN
2226-5147
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1445-1448
Název nakladatele
The European Acoustics Association
Místo vydání
Maastricht
Místo konání akce
Maastricht, Nizozemsko
Datum konání akce
31. 5. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce