A novel ZCS non-isolated bidirectional buck-boost DC-DC converter for energy storage applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F15%3A43925501" target="_blank" >RIV/49777513:23220/15:43925501 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7281647" target="_blank" >http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7281647</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ISIE.2015.7281647" target="_blank" >10.1109/ISIE.2015.7281647</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A novel ZCS non-isolated bidirectional buck-boost DC-DC converter for energy storage applications
Popis výsledku v původním jazyce
This paper proposes a new ZCS non-isolated bidirectional buck-boost DC-DC converter for energy storage applications. The conventional bidirectional converter was derived with auxiliary resonant cell to obtain ZCS turn-on/turnoff condition of the main switches. The proposed converter was operated in boost and buck modes with soft-switching operations in order to minimize the current stresses and switching losses, because the resonating current for the zero current switching does not flow through the mainswitches. The converter has an improved overall efficiency than the hard-switching converter, for high power energy storage applications. This paper mainly describes the operation principles of the proposed topology and experimental verification of theoretical analysis of the simulation results.
Název v anglickém jazyce
A novel ZCS non-isolated bidirectional buck-boost DC-DC converter for energy storage applications
Popis výsledku anglicky
This paper proposes a new ZCS non-isolated bidirectional buck-boost DC-DC converter for energy storage applications. The conventional bidirectional converter was derived with auxiliary resonant cell to obtain ZCS turn-on/turnoff condition of the main switches. The proposed converter was operated in boost and buck modes with soft-switching operations in order to minimize the current stresses and switching losses, because the resonating current for the zero current switching does not flow through the mainswitches. The converter has an improved overall efficiency than the hard-switching converter, for high power energy storage applications. This paper mainly describes the operation principles of the proposed topology and experimental verification of theoretical analysis of the simulation results.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)
ISBN
978-1-4673-7554-2
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1224-1229
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Buzios, Rio de Janeiro, Brazílie
Datum konání akce
3. 6. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—