Simulation of two cases steam turbine with synchronous generator during the switching into its self-consumption supply
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F15%3A43926220" target="_blank" >RIV/49777513:23220/15:43926220 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7165357" target="_blank" >http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7165357</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EEEIC.2015.7165357" target="_blank" >10.1109/EEEIC.2015.7165357</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simulation of two cases steam turbine with synchronous generator during the switching into its self-consumption supply
Popis výsledku v původním jazyce
This paper describes control of two cases steam turbine with synchronous generator which is switched into its self-consumption supply. The frequency in an electrical grid is stated on nominal value which is in the Union for the Coordination of the Transmission of Electricity (UCTE) grid 50 Hz. When deviation of the frequency is higher than 0.2 Hz, the switching of particular steam units into the island operation is only the chance how to maintain the supply of, at least, some small grids. The other possibility how to keep power units in operation, to be prepared for the next synchronization to the grid, is to switch them to operation status in which they supply only their self-consumption. This change of the operating state is the most dynamic load change for the control system of the unit. Simulation of switching of the urbogenerator into its selfconsumption is examined in MATLAB Simulink software.
Název v anglickém jazyce
Simulation of two cases steam turbine with synchronous generator during the switching into its self-consumption supply
Popis výsledku anglicky
This paper describes control of two cases steam turbine with synchronous generator which is switched into its self-consumption supply. The frequency in an electrical grid is stated on nominal value which is in the Union for the Coordination of the Transmission of Electricity (UCTE) grid 50 Hz. When deviation of the frequency is higher than 0.2 Hz, the switching of particular steam units into the island operation is only the chance how to maintain the supply of, at least, some small grids. The other possibility how to keep power units in operation, to be prepared for the next synchronization to the grid, is to switch them to operation status in which they supply only their self-consumption. This change of the operating state is the most dynamic load change for the control system of the unit. Simulation of switching of the urbogenerator into its selfconsumption is examined in MATLAB Simulink software.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2015 IEEE 15th International Conference on Environment and Electrical Engineering, EEEIC 2015 - Conference Proceedings
ISBN
978-1-4799-7993-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1298-1301
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Řím, Itálie
Datum konání akce
10. 6. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—