Analysis of delayed current zero occurrence within generator fed faults
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F15%3A43926355" target="_blank" >RIV/49777513:23220/15:43926355 - isvavai.cz</a>
Výsledek na webu
<a href="http://seen.fei.tuke.sk/documents/ee2015-proceedings.pdf" target="_blank" >http://seen.fei.tuke.sk/documents/ee2015-proceedings.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of delayed current zero occurrence within generator fed faults
Popis výsledku v původním jazyce
This paper discusses the possibility of occurrence of interrupted breaking due to the delayed current zero crossings. The analysis is aimed at a certain and specific application -- the main current branch of power output out of power plant. Breaking conditions change along with actual fault location and the configuration of the fault circuit and passive parameters (R, L, C) of it's elements. The paper evaluates the danger of interrupted breaking with emphasis on longer time intervals between current zeros and it's connection to reduced breaking capability in limitary areas of breaking characteristics due to longer arcing time, which can lead to total failure of the circuit breaker. The evaluation also contains the comparison between breaking characteristics of standard distribution circuit breakers and generator circuit breakers and detailed description of influence of each element on delayed current zeros.
Název v anglickém jazyce
Analysis of delayed current zero occurrence within generator fed faults
Popis výsledku anglicky
This paper discusses the possibility of occurrence of interrupted breaking due to the delayed current zero crossings. The analysis is aimed at a certain and specific application -- the main current branch of power output out of power plant. Breaking conditions change along with actual fault location and the configuration of the fault circuit and passive parameters (R, L, C) of it's elements. The paper evaluates the danger of interrupted breaking with emphasis on longer time intervals between current zeros and it's connection to reduced breaking capability in limitary areas of breaking characteristics due to longer arcing time, which can lead to total failure of the circuit breaker. The evaluation also contains the comparison between breaking characteristics of standard distribution circuit breakers and generator circuit breakers and detailed description of influence of each element on delayed current zeros.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 8th International Scientific Symposium on Electrical Power Engineering (ELEKTROENERGETIKA 2015)
ISBN
978-80-553-2187-5
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
376-379
Název nakladatele
Technical University of Košice
Místo vydání
Košice
Místo konání akce
Stará Lesná, Slovenská republika
Datum konání akce
16. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—