Current and voltage harmonics in high-rise prefabricated buildings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F16%3A43928841" target="_blank" >RIV/49777513:23220/16:43928841 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/document/7521730/" target="_blank" >http://ieeexplore.ieee.org/document/7521730/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE.2016.7521730" target="_blank" >10.1109/EPE.2016.7521730</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Current and voltage harmonics in high-rise prefabricated buildings
Popis výsledku v původním jazyce
Connecting a growing number of appliances in homes increases, in particular, the share of non-linear devices. Their operation causes harmonic currents which lead to deformed performances, and result in voltage distortions. This work is a study on the magnitude and order of current and voltage harmonics which may occur in power distribution within common prefabricated buildings. The basis for this work is measurement that was carried out in a typical urban residential area. At the same time, harmonic voltage was measured, including the total coefficient of distortion and currents in neutral conductors. The result is a determination of the operability of the power distribution system in civil building construction, with regard to compliance with standards in force.
Název v anglickém jazyce
Current and voltage harmonics in high-rise prefabricated buildings
Popis výsledku anglicky
Connecting a growing number of appliances in homes increases, in particular, the share of non-linear devices. Their operation causes harmonic currents which lead to deformed performances, and result in voltage distortions. This work is a study on the magnitude and order of current and voltage harmonics which may occur in power distribution within common prefabricated buildings. The basis for this work is measurement that was carried out in a typical urban residential area. At the same time, harmonic voltage was measured, including the total coefficient of distortion and currents in neutral conductors. The result is a determination of the operability of the power distribution system in civil building construction, with regard to compliance with standards in force.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2016 17th International Scientific Conference on Electric Power Engineering (EPE)
ISBN
978-1-5090-0907-7
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
269-274
Název nakladatele
Czech Technical University in Prague
Místo vydání
Prague
Místo konání akce
Praha, Česká republika
Datum konání akce
16. 5. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000382934600016