Popis výsledku v původním jazyce
This paper presents a research focused on comparison of two types of textile electrodes for continuous measurement of electrocardiogram (ECG) signals. We designed and realized knitted and embroidered textile electrodes, which were integrated in a sport top, chest strap and a functional T-shirt respectively. The integration of the electrodes was done in close cooperation of two SME textile companies. The knitted textrodes were made of silveR.STAT(R) and X-STATIC monofil continuous fibres. The fibres have a polyamide core coated with thin pure silver layer which makes them conductive, flexible, washable and anti-bacterial. The embroidered textrodes were realized from a developed high conductive hybrid thread. Object of this research are fully integrated and skin friendly embroidered and knitted electrodes, which will bring patients and convalescents more comfort and freedom. Medlab EG0500 module was used for ECG measurement and Raspberry pi for data processing and communication.
Název v anglickém jazyce
A comparison of embroidered and woven textile electrodes for continuous measurement of ECG
Popis výsledku anglicky
This paper presents a research focused on comparison of two types of textile electrodes for continuous measurement of electrocardiogram (ECG) signals. We designed and realized knitted and embroidered textile electrodes, which were integrated in a sport top, chest strap and a functional T-shirt respectively. The integration of the electrodes was done in close cooperation of two SME textile companies. The knitted textrodes were made of silveR.STAT(R) and X-STATIC monofil continuous fibres. The fibres have a polyamide core coated with thin pure silver layer which makes them conductive, flexible, washable and anti-bacterial. The embroidered textrodes were realized from a developed high conductive hybrid thread. Object of this research are fully integrated and skin friendly embroidered and knitted electrodes, which will bring patients and convalescents more comfort and freedom. Medlab EG0500 module was used for ECG measurement and Raspberry pi for data processing and communication.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Spring Seminar of Electronics Technology (ISSE 2016)
ISBN
978-1-5090-1389-0
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
7-11
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Pilsen, Czech Republic
Datum konání akce
18. 5. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000387089800002