Monitoring device of resin curing process
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F16%3A43928900" target="_blank" >RIV/49777513:23220/16:43928900 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/document/7563239/" target="_blank" >http://ieeexplore.ieee.org/document/7563239/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ISSE.2016.7563239" target="_blank" >10.1109/ISSE.2016.7563239</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Monitoring device of resin curing process
Popis výsledku v původním jazyce
The presented article introduces a system for resin curing monitoring. The system is based on a combined sensor built on a ceramic substrate containing a heating element for independent surface heating, interdigital electrodes, and a Pt1000 thermistor for precise temperature measurements. The idea of the simple resin curing monitoring device is based on a small amount of tested resin being applied directly to the sensor surface. After the resin has been applied to the surface, a controlled heating process begins together with the measurement of the electrical properties of the resin, usually the impedance. The curing process is thus monitored and graphically plotted on the connected PC.
Název v anglickém jazyce
Monitoring device of resin curing process
Popis výsledku anglicky
The presented article introduces a system for resin curing monitoring. The system is based on a combined sensor built on a ceramic substrate containing a heating element for independent surface heating, interdigital electrodes, and a Pt1000 thermistor for precise temperature measurements. The idea of the simple resin curing monitoring device is based on a small amount of tested resin being applied directly to the sensor surface. After the resin has been applied to the surface, a controlled heating process begins together with the measurement of the electrical properties of the resin, usually the impedance. The curing process is thus monitored and graphically plotted on the connected PC.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1607" target="_blank" >LO1607: RICE – Nové technologie a koncepce pro inteligentní průmyslové systémy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Spring Seminar of Electronics Technology (ISSE 2016)
ISBN
978-1-5090-1389-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
452-455
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Pilsen, Czech Republic
Datum konání akce
18. 5. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000387089800089