Popis výsledku v původním jazyce
Demands on current electrical insulating systems have increasing trend toward tolerance to environmental safe conditions. This trend of course subsequently requires finding a new way in the field of application of materials compatible with the surrounding environment, e.g. easy biodegradable. This applies particularly for electrical insulating liquids used in distribution transformers since their deployment is in large numbers - 50, 000 pieces only in the Czech Republic - are often in areas with increased demands on the environment - urban areas, natural preserves or close water sources. These electrical insulating fluid therefore has excellent electrical insulation properties in addition having another important feature - are biodegradable. Therefore, when eventual unwanted leakage was occurring, they are absorbed by soil bacteria and it is not necessary to perform sanitization of the soil. This is advantage to the petroleum products. Fluids, which are in this area currently in center of legitimate interest, are natural esters. Their introduction to full application will however require the implementation of a number of following studies so that these substances can fully cope with properties of currently used mineral oils. Mineral oils have excellent electrical properties, but they are intolerant to the environment. One of the essential aspects of the verification of the long-term durability of natural esters, namely the rapeseed oil to long term thermal exposure. This verification is necessary for electrical insulation fluids especially because of their operation in transformers, where they become liquid component of the insulating system. The liquid in ransformer are subjected to permanent thermal stresses during operating mode. The aim of this study was therefore to investigate the life time of natural esters and compared it with selected synthetic and mineral oil.
Název v anglickém jazyce
Validation of condition of natural esters
Popis výsledku anglicky
Demands on current electrical insulating systems have increasing trend toward tolerance to environmental safe conditions. This trend of course subsequently requires finding a new way in the field of application of materials compatible with the surrounding environment, e.g. easy biodegradable. This applies particularly for electrical insulating liquids used in distribution transformers since their deployment is in large numbers - 50, 000 pieces only in the Czech Republic - are often in areas with increased demands on the environment - urban areas, natural preserves or close water sources. These electrical insulating fluid therefore has excellent electrical insulation properties in addition having another important feature - are biodegradable. Therefore, when eventual unwanted leakage was occurring, they are absorbed by soil bacteria and it is not necessary to perform sanitization of the soil. This is advantage to the petroleum products. Fluids, which are in this area currently in center of legitimate interest, are natural esters. Their introduction to full application will however require the implementation of a number of following studies so that these substances can fully cope with properties of currently used mineral oils. Mineral oils have excellent electrical properties, but they are intolerant to the environment. One of the essential aspects of the verification of the long-term durability of natural esters, namely the rapeseed oil to long term thermal exposure. This verification is necessary for electrical insulation fluids especially because of their operation in transformers, where they become liquid component of the insulating system. The liquid in ransformer are subjected to permanent thermal stresses during operating mode. The aim of this study was therefore to investigate the life time of natural esters and compared it with selected synthetic and mineral oil.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of International Conference on Diagnostic of Electrical Machines and Insulating Systems in Electrical Engineering (DEMISEE 2016)
ISBN
978-1-5090-1249-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
85-88
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Papradno, Slovensko
Datum konání akce
20. 6. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000383221400019