Reactive power in circuits with sampled resistive load
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F17%3A43949427" target="_blank" >RIV/49777513:23220/17:43949427 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.degruyter.com/view/j/jee.2017.68.issue-5/jee-2017-0067/jee-2017-0067.xml?format=INT" target="_blank" >https://www.degruyter.com/view/j/jee.2017.68.issue-5/jee-2017-0067/jee-2017-0067.xml?format=INT</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/jee-2017-0067" target="_blank" >10.1515/jee-2017-0067</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reactive power in circuits with sampled resistive load
Popis výsledku v původním jazyce
The process of power transmission lines, from source to load is a well-known, if the voltages and currents vary harmonically. With the lines is transmitted active power that is dissipated in load (this power exits from the system) and reactive power (this power oscillates between the source and the load). Note that it would be more appropriate designation the external power and the internal power. Such systems are known as cyclo-dissipative. The active power is dissipated in the load and the reactive power oscillates between the source and the load. Physically, reactive power is delivered to reactive elements of load. Transmitting reactive power increases Joule’s losses and voltage drops on lines. Reactive power can be compensated in a known manner. Compensation reduces the effective value of the current in the line. To the case of periodic but non-sinusoidal voltages and currents has been devoted many publications, conferences, etc. during the past 100 years. But despite much effort, this problem has not yet been fully solved. In the present article, we show that in a system with a harmonic source of voltage even in the case of a linear pure resistive load a reactive power can be generated and can be compensated. A necessary, but not sufficient, condition is that the resistive load is time-varying. The presented study deals with a periodically sampled resistive load.
Název v anglickém jazyce
Reactive power in circuits with sampled resistive load
Popis výsledku anglicky
The process of power transmission lines, from source to load is a well-known, if the voltages and currents vary harmonically. With the lines is transmitted active power that is dissipated in load (this power exits from the system) and reactive power (this power oscillates between the source and the load). Note that it would be more appropriate designation the external power and the internal power. Such systems are known as cyclo-dissipative. The active power is dissipated in the load and the reactive power oscillates between the source and the load. Physically, reactive power is delivered to reactive elements of load. Transmitting reactive power increases Joule’s losses and voltage drops on lines. Reactive power can be compensated in a known manner. Compensation reduces the effective value of the current in the line. To the case of periodic but non-sinusoidal voltages and currents has been devoted many publications, conferences, etc. during the past 100 years. But despite much effort, this problem has not yet been fully solved. In the present article, we show that in a system with a harmonic source of voltage even in the case of a linear pure resistive load a reactive power can be generated and can be compensated. A necessary, but not sufficient, condition is that the resistive load is time-varying. The presented study deals with a periodically sampled resistive load.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1607" target="_blank" >LO1607: RICE – Nové technologie a koncepce pro inteligentní průmyslové systémy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Electrical Engineering = Elektrotechnický časopis
ISSN
1335-3632
e-ISSN
—
Svazek periodika
68
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
7
Strana od-do
357-363
Kód UT WoS článku
000418491200004
EID výsledku v databázi Scopus
2-s2.0-85037671292