Modified pulse sequence analysis for PD measurement at DC
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F18%3A43951531" target="_blank" >RIV/49777513:23220/18:43951531 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8514785" target="_blank" >https://ieeexplore.ieee.org/document/8514785</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICD.2018.8514785" target="_blank" >10.1109/ICD.2018.8514785</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modified pulse sequence analysis for PD measurement at DC
Popis výsledku v původním jazyce
The Partial Discharge Behavior at DC conditions is currently investigated worldwide to find out an appropriate method and/ or principle for quality testing of HVDC components. Due to the lack of knowledge concerns a lot of basic investigations is performed. These kind of investigations should be continued also for other arrangements like surface discharge and cavity discharge test sets. The paper deals with results of PD measurement at a simple corona test set – needle-to- plane – under DC conditions using the Pulse Sequence Analysis of the PD behavior. For better understanding of the measured data some comparison measurement at AC conditions were performed. Despite of some differences in the PD behavior it could be shown, that the parameters cumulative charge Qsum and dQ/ dt are the most important parameters for characterizing the PD behavior at DC conditions. Additionally, the measuring time in depending on the insulation type is of great importance too, which was confirmed by a special arrangement – corona with insulating sheet. The method of cumulative charge and the PSA analysis were used to determine the partial discharge activity at AC and DC conditions. There was shown the differences between the cases of measurement without and with an insulating sheet between the electrodes. It seems to be that the parameter ΔQ/Δt could be useful for better understanding of the PD behavior and should be measured at further investigations.
Název v anglickém jazyce
Modified pulse sequence analysis for PD measurement at DC
Popis výsledku anglicky
The Partial Discharge Behavior at DC conditions is currently investigated worldwide to find out an appropriate method and/ or principle for quality testing of HVDC components. Due to the lack of knowledge concerns a lot of basic investigations is performed. These kind of investigations should be continued also for other arrangements like surface discharge and cavity discharge test sets. The paper deals with results of PD measurement at a simple corona test set – needle-to- plane – under DC conditions using the Pulse Sequence Analysis of the PD behavior. For better understanding of the measured data some comparison measurement at AC conditions were performed. Despite of some differences in the PD behavior it could be shown, that the parameters cumulative charge Qsum and dQ/ dt are the most important parameters for characterizing the PD behavior at DC conditions. Additionally, the measuring time in depending on the insulation type is of great importance too, which was confirmed by a special arrangement – corona with insulating sheet. The method of cumulative charge and the PSA analysis were used to determine the partial discharge activity at AC and DC conditions. There was shown the differences between the cases of measurement without and with an insulating sheet between the electrodes. It seems to be that the parameter ΔQ/Δt could be useful for better understanding of the PD behavior and should be measured at further investigations.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1607" target="_blank" >LO1607: RICE – Nové technologie a koncepce pro inteligentní průmyslové systémy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2018 IEEE 2nd International Conference on Dielectrics (ICD) : /proceedings/
ISBN
978-1-5386-6389-9
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Budapest, Hungary
Datum konání akce
1. 7. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000446959700183