PWM for open-end winding drive in fault tolerant mode with minimum infinity norm calculation of modulation signals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F18%3A43952545" target="_blank" >RIV/49777513:23220/18:43952545 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8591262" target="_blank" >https://ieeexplore.ieee.org/document/8591262</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/IECON.2018.8591262" target="_blank" >10.1109/IECON.2018.8591262</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
PWM for open-end winding drive in fault tolerant mode with minimum infinity norm calculation of modulation signals
Popis výsledku v původním jazyce
A carrier-based PWM technique proposed for openend winding drives, which are fed from dual three-phase inverters, is discussed in the paper. The proposed method is based on minimization of infinity norm of a searched vector containing instantaneous modulation values, entering PWM blocks of both inverters. Due to the optimization criterion, the proposed technique is able to generate optimized modulation signals ensuring high utilization of the dc-link voltage and achieve comparable performance to classical SVPWM in the normal operation mode. However, besides the normal mode, the method discussed in the paper is designed for attractive fault tolerant operation mode which enables to significantly increase robustness and reliability of an electric drive.
Název v anglickém jazyce
PWM for open-end winding drive in fault tolerant mode with minimum infinity norm calculation of modulation signals
Popis výsledku anglicky
A carrier-based PWM technique proposed for openend winding drives, which are fed from dual three-phase inverters, is discussed in the paper. The proposed method is based on minimization of infinity norm of a searched vector containing instantaneous modulation values, entering PWM blocks of both inverters. Due to the optimization criterion, the proposed technique is able to generate optimized modulation signals ensuring high utilization of the dc-link voltage and achieve comparable performance to classical SVPWM in the normal operation mode. However, besides the normal mode, the method discussed in the paper is designed for attractive fault tolerant operation mode which enables to significantly increase robustness and reliability of an electric drive.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1607" target="_blank" >LO1607: RICE – Nové technologie a koncepce pro inteligentní průmyslové systémy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings : IECON 2018 : 44th Annual Conference of the IEEE Industrial Electronics Society
ISBN
978-1-5090-6684-1
ISSN
1553-572X
e-ISSN
2577-1647
Počet stran výsledku
6
Strana od-do
5849-5854
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Washington DC, USA
Datum konání akce
20. 10. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000505811105123