Study of power consumption of Timepix3 detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F19%3A43954116" target="_blank" >RIV/49777513:23220/19:43954116 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/19:00328608
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1748-0221/14/01/C01001/meta" target="_blank" >https://iopscience.iop.org/article/10.1088/1748-0221/14/01/C01001/meta</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/14/01/C01001" target="_blank" >10.1088/1748-0221/14/01/C01001</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of power consumption of Timepix3 detector
Popis výsledku v původním jazyce
The Timepix3 readout chip - the latest member of the Medipix family of hybrid pixel detectors - brought several new functionalities in comparison with the older Timepix, i.e. a high hit-rate, a time granularity of 1.5625 ns, a data-driven readout scheme (with a per pixel dead time of approximately 475 ns), and the capability of measuring Time-over-Threshold (ToT) and Time-of-Arrival (ToA) in each pixel at the same time. However, the high power consumption of the Timepix3 in the standard setting prevents its use in applications with limited power budget. Moreover, the high power consumption poses the risk of overheating the sensor so that proper cooling is crucial. The presented work investigates the effect of different settings in the analogue and a digital part of the Timepix3 detector on its power consumption. Measurements were performed with the Timepix3 chipboard. The firmware of the Katherine readout was modified so that the user can monitor the power consumptions of analogue and digital part "on-line" (directly in the control software). In standard settings, a power consumption of approximately 1.3 W was found. By changes of internal DACs, the consumption could be reduced to 650 mW. Further reduction was achieved by the change of the clock management in the digital part of the Timepix3. In result, a power consumption of 216 mA could be achieved. In these low power settings, the ToA clock was reduced to 10 MHz and thus the time binning was 100 ns. The energy resolution was not affected significantly. The pixel dead time is also negatively affected when the matrix clock is reduced. In the case of 10 MHz, the minimal per pixel dead time is 1.9 mu s.
Název v anglickém jazyce
Study of power consumption of Timepix3 detector
Popis výsledku anglicky
The Timepix3 readout chip - the latest member of the Medipix family of hybrid pixel detectors - brought several new functionalities in comparison with the older Timepix, i.e. a high hit-rate, a time granularity of 1.5625 ns, a data-driven readout scheme (with a per pixel dead time of approximately 475 ns), and the capability of measuring Time-over-Threshold (ToT) and Time-of-Arrival (ToA) in each pixel at the same time. However, the high power consumption of the Timepix3 in the standard setting prevents its use in applications with limited power budget. Moreover, the high power consumption poses the risk of overheating the sensor so that proper cooling is crucial. The presented work investigates the effect of different settings in the analogue and a digital part of the Timepix3 detector on its power consumption. Measurements were performed with the Timepix3 chipboard. The firmware of the Katherine readout was modified so that the user can monitor the power consumptions of analogue and digital part "on-line" (directly in the control software). In standard settings, a power consumption of approximately 1.3 W was found. By changes of internal DACs, the consumption could be reduced to 650 mW. Further reduction was achieved by the change of the clock management in the digital part of the Timepix3. In result, a power consumption of 216 mA could be achieved. In these low power settings, the ToA clock was reduced to 10 MHz and thus the time binning was 100 ns. The energy resolution was not affected significantly. The pixel dead time is also negatively affected when the matrix clock is reduced. In the case of 10 MHz, the minimal per pixel dead time is 1.9 mu s.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
January
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
0-10
Kód UT WoS článku
000454851900001
EID výsledku v databázi Scopus
2-s2.0-85062558502