Ventilation system with skewed rotor cooling ducts of 40-MW synchronous machine: a case study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F19%3A43954937" target="_blank" >RIV/49777513:23220/19:43954937 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/content/pdf/10.1007%2Fs00202-019-00767-z.pdf" target="_blank" >https://link.springer.com/content/pdf/10.1007%2Fs00202-019-00767-z.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00202-019-00767-z" target="_blank" >10.1007/s00202-019-00767-z</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ventilation system with skewed rotor cooling ducts of 40-MW synchronous machine: a case study
Popis výsledku v původním jazyce
This paper describes modified ventilation system and thermal analysis of low-power 40-MW turbo generator. The study compares thermal behaviour of the machine for three different arrangements of the rotor ventilation ducts. Variations of both the sub-slot and the radial ducts are analysed. The described work follows up on the ventilation calculation done in past. In particular, there are several options tested to figure out the behaviour of the numerical model. The original design ventilation part of the numerical model was tuned according to measurement. The results show advantages and disadvantages of those options and also show the way how to improve the cooling system of a turbo generator. All given theoretical results are commented and properly concluded.
Název v anglickém jazyce
Ventilation system with skewed rotor cooling ducts of 40-MW synchronous machine: a case study
Popis výsledku anglicky
This paper describes modified ventilation system and thermal analysis of low-power 40-MW turbo generator. The study compares thermal behaviour of the machine for three different arrangements of the rotor ventilation ducts. Variations of both the sub-slot and the radial ducts are analysed. The described work follows up on the ventilation calculation done in past. In particular, there are several options tested to figure out the behaviour of the numerical model. The original design ventilation part of the numerical model was tuned according to measurement. The results show advantages and disadvantages of those options and also show the way how to improve the cooling system of a turbo generator. All given theoretical results are commented and properly concluded.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1607" target="_blank" >LO1607: RICE – Nové technologie a koncepce pro inteligentní průmyslové systémy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrical Engineering. Archiv für Elektrotechnik
ISSN
0948-7921
e-ISSN
—
Svazek periodika
101
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
203-211
Kód UT WoS článku
000468966400017
EID výsledku v databázi Scopus
2-s2.0-85066148721