Continuity of supply can be regulated by a national regulation authority to maintain or improve its level. Short interruptions are monitored and regulated much less frequently than long interruptions. They can occur as single event or in sequences cased by a single power system event or by independent events. Frequency of their occurrence is mainly characterized by the indicator MAIFI. Method used for counting interruption sequences greatly affects the values of the indicator. In regulatory framework, it is important to define continuity of supply indicators and to establish procedures for counting of interruptions. The presented work is initial step in preparation of methodology for MAIFI calculation in the Czech Republic. In the paper, long-term monitoring of events in selected MV/LV substations is evaluated. Number and percentage of short and long interruptions during monitoring period is shown. Values of MAIFI indicator are compared with values of modified indicator that besides short interruptions includes also severe voltage dips. The effect of various aggregation methods and time-aggregation intervals for counting of short interruptions is illustrated on the case of a MV/LV substation with extreme occurrence of short interruptions.
Název v anglickém jazyce
Evaluation of short interruptions of supply voltage in distribution system
Popis výsledku anglicky
Continuity of supply can be regulated by a national regulation authority to maintain or improve its level. Short interruptions are monitored and regulated much less frequently than long interruptions. They can occur as single event or in sequences cased by a single power system event or by independent events. Frequency of their occurrence is mainly characterized by the indicator MAIFI. Method used for counting interruption sequences greatly affects the values of the indicator. In regulatory framework, it is important to define continuity of supply indicators and to establish procedures for counting of interruptions. The presented work is initial step in preparation of methodology for MAIFI calculation in the Czech Republic. In the paper, long-term monitoring of events in selected MV/LV substations is evaluated. Number and percentage of short and long interruptions during monitoring period is shown. Values of MAIFI indicator are compared with values of modified indicator that besides short interruptions includes also severe voltage dips. The effect of various aggregation methods and time-aggregation intervals for counting of short interruptions is illustrated on the case of a MV/LV substation with extreme occurrence of short interruptions.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 10th International Scientific Symposium on Electrical Power Engineering (ELEKTROENERGETIKA 2019)
ISBN
978-80-553-3324-3
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
111-115
Název nakladatele
Technical University of Košice
Místo vydání
Košice
Místo konání akce
Stará Lesná, Slovenská republika
Datum konání akce
16. 9. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—