Relative luminosity measurement with Timepix3 in ATLAS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F20%3A43958529" target="_blank" >RIV/49777513:23220/20:43958529 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/20:00341384
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1748-0221/15/01/C01039" target="_blank" >https://iopscience.iop.org/article/10.1088/1748-0221/15/01/C01039</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/15/01/C01039" target="_blank" >10.1088/1748-0221/15/01/C01039</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Relative luminosity measurement with Timepix3 in ATLAS
Popis výsledku v původním jazyce
The capability of Timepix3 detectors installed in ATLAS to measure luminosity is evaluated. It is described how noisy pixels are identified and excluded. Two different methods for luminosity determination, i.e. cluster counting and thermal neutron counting are described and compared with each other. The achieved short-term relative precision with both methods is determined by modeling the luminosity curve. It is shown that using cluster counting a short-term relative precision of < 0:5% can be achieved for 60 s time intervals. For thermal neutrons, a short-term relative precision (for 60 s intervals) of 2% was found. Hereby statistics was the limiting factor. The findings are discussed in view of Timepix3 upgrade plans for LHC Run-3.
Název v anglickém jazyce
Relative luminosity measurement with Timepix3 in ATLAS
Popis výsledku anglicky
The capability of Timepix3 detectors installed in ATLAS to measure luminosity is evaluated. It is described how noisy pixels are identified and excluded. Two different methods for luminosity determination, i.e. cluster counting and thermal neutron counting are described and compared with each other. The achieved short-term relative precision with both methods is determined by modeling the luminosity curve. It is shown that using cluster counting a short-term relative precision of < 0:5% can be achieved for 60 s time intervals. For thermal neutrons, a short-term relative precision (for 60 s intervals) of 2% was found. Hereby statistics was the limiting factor. The findings are discussed in view of Timepix3 upgrade plans for LHC Run-3.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
0-13
Kód UT WoS článku
000525449100039
EID výsledku v databázi Scopus
2-s2.0-85081686489