Advantage of redesign of cooling system 40MW synchronous machine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F20%3A43959351" target="_blank" >RIV/49777513:23220/20:43959351 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/9270940" target="_blank" >https://ieeexplore.ieee.org/document/9270940</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICEM49940.2020.9270940" target="_blank" >10.1109/ICEM49940.2020.9270940</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Advantage of redesign of cooling system 40MW synchronous machine
Popis výsledku v původním jazyce
The main goal of this work is in the qualification of temperature changes due to design modifications of the medium-sized turbo generator with the output power 40 MW, ie the temperature distribution of the active parts. The work summarizes of designing a number of changes in the cooling system of a 40 MW synchronous machine. The work is based on ventilation and thermal calculations to verify the change in flow rates, respectively, the flow rate of cooling air in the machine. Individual changes are first analyzed separately and then compared with the original state. Temperature trends and their comparison with the original solution are used to evaluate the impacts of design changes.
Název v anglickém jazyce
Advantage of redesign of cooling system 40MW synchronous machine
Popis výsledku anglicky
The main goal of this work is in the qualification of temperature changes due to design modifications of the medium-sized turbo generator with the output power 40 MW, ie the temperature distribution of the active parts. The work summarizes of designing a number of changes in the cooling system of a 40 MW synchronous machine. The work is based on ventilation and thermal calculations to verify the change in flow rates, respectively, the flow rate of cooling air in the machine. Individual changes are first analyzed separately and then compared with the original state. Temperature trends and their comparison with the original solution are used to evaluate the impacts of design changes.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF18_069%2F0009855" target="_blank" >EF18_069/0009855: Elektrotechnické technologie s vysokým podílem vestavěné inteligence</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings : 2020 International Conference on Electrical Machines (ICEM 2020)
ISBN
978-1-72819-945-0
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
765-771
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
virtual, Gothenburg, Sweden
Datum konání akce
23. 8. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—