Four-leg transformer with defined zero sequence impedance for ground fault compensation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F21%3A43962697" target="_blank" >RIV/49777513:23220/21:43962697 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/9542922" target="_blank" >https://ieeexplore.ieee.org/document/9542922</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.23919/AE51540.2021.9542922" target="_blank" >10.23919/AE51540.2021.9542922</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Four-leg transformer with defined zero sequence impedance for ground fault compensation
Popis výsledku v původním jazyce
Single-phase ground faults are the most common faults in medium-voltage distribution grids. High-impedance grid grounding using a special four-leg transformer is discussed in the paper. The transformer’s zero-sequence impedance differs from positive-sequence impedance and it is designed to compensate the earth faults currents in Medium Voltage (MV) distribution grids when single-phase ground fault occurs. The designed transformer can replace the traditional arc suppression coils (ASC) in the case where no distribution transformer neutral is available or distributed compensation is required. Alternatively, the transformer can operate in parallel with the ASC.
Název v anglickém jazyce
Four-leg transformer with defined zero sequence impedance for ground fault compensation
Popis výsledku anglicky
Single-phase ground faults are the most common faults in medium-voltage distribution grids. High-impedance grid grounding using a special four-leg transformer is discussed in the paper. The transformer’s zero-sequence impedance differs from positive-sequence impedance and it is designed to compensate the earth faults currents in Medium Voltage (MV) distribution grids when single-phase ground fault occurs. The designed transformer can replace the traditional arc suppression coils (ASC) in the case where no distribution transformer neutral is available or distributed compensation is required. Alternatively, the transformer can operate in parallel with the ASC.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Conference on Applied Electronics (AE 2021) : /proceedings/
ISBN
978-80-261-0972-3
ISSN
1803-7232
e-ISSN
1805-9597
Počet stran výsledku
7
Strana od-do
157-163
Název nakladatele
University of West Bohemia
Místo vydání
Pilsen
Místo konání akce
Pilsen, Czech Republic
Datum konání akce
7. 9. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—