Real-time fault detection algorithm for interior permanent magnet synchronous motor drive using DSP/FPGA
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F22%3A43965262" target="_blank" >RIV/49777513:23220/22:43965262 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/9831681" target="_blank" >https://ieeexplore.ieee.org/document/9831681</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ISIE51582.2022.9831681" target="_blank" >10.1109/ISIE51582.2022.9831681</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Real-time fault detection algorithm for interior permanent magnet synchronous motor drive using DSP/FPGA
Popis výsledku v původním jazyce
The paper deals with the design, implementation and experiment of an embedded drive system diagnostics for interior permanent magnet synchronous motor drive for safety critical applications. The drive is intended for traction drive applications therefore it uses a combination of a digital signal processor (DSP) and a field programmable gate array (FPGA) as is often the case in modern industrial drives. A real-time harmonic monitoring is employed to indicate the development or existence of fault within the drive system. This is achieved by embedding a real-time measurement and control within the DSP operating in conjunction with the motor control, to estimate the machine’s transient reactance after applying an excitation with voltage pulses using the switching of the inverter, and a real-time frequency analysis of the parameter within the FPGA operating independently of the motor control. Experimental testing is used to validate the proposed condition monitoring algorithm on a laboratory prototype of interior permanent magnet synchronous motor drive with a rated power of 4.5 kW.
Název v anglickém jazyce
Real-time fault detection algorithm for interior permanent magnet synchronous motor drive using DSP/FPGA
Popis výsledku anglicky
The paper deals with the design, implementation and experiment of an embedded drive system diagnostics for interior permanent magnet synchronous motor drive for safety critical applications. The drive is intended for traction drive applications therefore it uses a combination of a digital signal processor (DSP) and a field programmable gate array (FPGA) as is often the case in modern industrial drives. A real-time harmonic monitoring is employed to indicate the development or existence of fault within the drive system. This is achieved by embedding a real-time measurement and control within the DSP operating in conjunction with the motor control, to estimate the machine’s transient reactance after applying an excitation with voltage pulses using the switching of the inverter, and a real-time frequency analysis of the parameter within the FPGA operating independently of the motor control. Experimental testing is used to validate the proposed condition monitoring algorithm on a laboratory prototype of interior permanent magnet synchronous motor drive with a rated power of 4.5 kW.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2022 IEEE 31st International Symposium on Industrial Electronics (ISIE) : /proceedings/
ISBN
978-1-66548-240-0
ISSN
2163-5145
e-ISSN
—
Počet stran výsledku
6
Strana od-do
655-660
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Anchorage, Alaska, USA
Datum konání akce
1. 6. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000946662000105