Different approach for anaerobic threshold approximation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F22%3A43965272" target="_blank" >RIV/49777513:23220/22:43965272 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/9797109" target="_blank" >https://ieeexplore.ieee.org/document/9797109</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/MECO55406.2022.9797109" target="_blank" >10.1109/MECO55406.2022.9797109</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Different approach for anaerobic threshold approximation
Popis výsledku v původním jazyce
In this paper the 2 different approach for anaerobic threshold (AnT) determination and approximation were described. Anaerobic thresholds were calculated for athletes tested on a bicycle ergometer and treadmill ergometer where the heart rate (HR) and pulmonary ventilation parameters (VE), oxygen consumption (VO2) and carbon dioxide expenditure (VCO2) were continuously measured. The first methods for AnT calculations are based on invasive lactate (LA) measurement. For comparison, a non-invasive method based on changing the course of ventilation parameters during exercise is briefly presented. However, the main goal of the paper was the possibility of minimizing the number of blood sampling for lactate measurements from which the lactate curve and anaerobic threshold can be determined. The Matlab program was used to process the calculations.
Název v anglickém jazyce
Different approach for anaerobic threshold approximation
Popis výsledku anglicky
In this paper the 2 different approach for anaerobic threshold (AnT) determination and approximation were described. Anaerobic thresholds were calculated for athletes tested on a bicycle ergometer and treadmill ergometer where the heart rate (HR) and pulmonary ventilation parameters (VE), oxygen consumption (VO2) and carbon dioxide expenditure (VCO2) were continuously measured. The first methods for AnT calculations are based on invasive lactate (LA) measurement. For comparison, a non-invasive method based on changing the course of ventilation parameters during exercise is briefly presented. However, the main goal of the paper was the possibility of minimizing the number of blood sampling for lactate measurements from which the lactate curve and anaerobic threshold can be determined. The Matlab program was used to process the calculations.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF18_069%2F0009855" target="_blank" >EF18_069/0009855: Elektrotechnické technologie s vysokým podílem vestavěné inteligence</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2022 11th Mediterranean Conference on Embedded Computing (MECO) : proceedings
ISBN
978-1-66546-828-2
ISSN
—
e-ISSN
2637-9511
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Budva, Montenegro
Datum konání akce
7. 6. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000855969800101