Comparison of Bicycle and Treadmill Ergometer Workload
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F23%3A43969890" target="_blank" >RIV/49777513:23220/23:43969890 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/10274231" target="_blank" >https://ieeexplore.ieee.org/document/10274231</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/AE58099.2023.10274231" target="_blank" >10.1109/AE58099.2023.10274231</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Bicycle and Treadmill Ergometer Workload
Popis výsledku v původním jazyce
This paper describes a method for comparison exercise intensity (workload) based on oxygen consumption (V̇O 2 ) and carbon dioxide expenditure (V̇CO 2 ) during the bicycle ergometer and treadmill ergometer stress tests. During the stress test, values of heart rate (HR), pulmonary ventilation (V̇E), oxygen consumption and carbon dioxide expenditure were continuously measured from the start of the test until exhaustion. The main goal of the study was to find out whether it is possible to compare the value of the load intensity on a treadmill ergometer, where the load is characterized by the running speed and the incline, with the load on a bicycle ergometer, where the load is given in Watts. The results can also be used to possibly derive a mathematical model of the test subject. The results were confirmed by a number of measurements.
Název v anglickém jazyce
Comparison of Bicycle and Treadmill Ergometer Workload
Popis výsledku anglicky
This paper describes a method for comparison exercise intensity (workload) based on oxygen consumption (V̇O 2 ) and carbon dioxide expenditure (V̇CO 2 ) during the bicycle ergometer and treadmill ergometer stress tests. During the stress test, values of heart rate (HR), pulmonary ventilation (V̇E), oxygen consumption and carbon dioxide expenditure were continuously measured from the start of the test until exhaustion. The main goal of the study was to find out whether it is possible to compare the value of the load intensity on a treadmill ergometer, where the load is characterized by the running speed and the incline, with the load on a bicycle ergometer, where the load is given in Watts. The results can also be used to possibly derive a mathematical model of the test subject. The results were confirmed by a number of measurements.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF18_069%2F0009855" target="_blank" >EF18_069/0009855: Elektrotechnické technologie s vysokým podílem vestavěné inteligence</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Conference on Applied Electronics (AE 2023) : /proceedings/
ISBN
979-8-3503-3553-8
ISSN
1803-7232
e-ISSN
—
Počet stran výsledku
4
Strana od-do
139-142
Název nakladatele
University of West Bohemia
Místo vydání
Pilsen
Místo konání akce
Pilsen, Czech Republic
Datum konání akce
6. 9. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce