Neutron/gamma scintillation detector for status monitoring of accelerator-driven neutron source IREN
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F24%3A43971653" target="_blank" >RIV/49777513:23220/24:43971653 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/24:00373174
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1738573323005727?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1738573323005727?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.net.2023.12.020" target="_blank" >10.1016/j.net.2023.12.020</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Neutron/gamma scintillation detector for status monitoring of accelerator-driven neutron source IREN
Popis výsledku v původním jazyce
This paper presents a neutron/gamma detector based on a micropixel avalanche photodiode and a plastic scintillator that monitors the status of the accelerator-driven intense resonance neutron source (IREN) facility by measuring the neutron/gamma intensity in the target hall. The electronics of the neutron/gamma detector has been designed and developed. The size of the plastic scintillator was selected to be 3.7 × 3.7 × 30 mm3 due to the sensitive area of the MAPD. The experimental results demonstrated a dependence between the count rate of the detector and the frequency of the accelerator. The detector is sensitive to intermediate and fast neutrons. The minimum detectable energy was determined to be 200 keV using Cs-137 point gamma source. The maximum counting rate of the detector from TTL out is about 2.2·106 counts/sec, but for analogue output it is about 2·107 counts/sec. The detector can not allow discriminating neutrons and gamma rays by charge integration method.
Název v anglickém jazyce
Neutron/gamma scintillation detector for status monitoring of accelerator-driven neutron source IREN
Popis výsledku anglicky
This paper presents a neutron/gamma detector based on a micropixel avalanche photodiode and a plastic scintillator that monitors the status of the accelerator-driven intense resonance neutron source (IREN) facility by measuring the neutron/gamma intensity in the target hall. The electronics of the neutron/gamma detector has been designed and developed. The size of the plastic scintillator was selected to be 3.7 × 3.7 × 30 mm3 due to the sensitive area of the MAPD. The experimental results demonstrated a dependence between the count rate of the detector and the frequency of the accelerator. The detector is sensitive to intermediate and fast neutrons. The minimum detectable energy was determined to be 200 keV using Cs-137 point gamma source. The maximum counting rate of the detector from TTL out is about 2.2·106 counts/sec, but for analogue output it is about 2·107 counts/sec. The detector can not allow discriminating neutrons and gamma rays by charge integration method.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Engineering and Technology
ISSN
1738-5733
e-ISSN
1738-5733
Svazek periodika
56
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
KP - Korejská lidově demokratická republika
Počet stran výsledku
5
Strana od-do
1667-1671
Kód UT WoS článku
001237715700004
EID výsledku v databázi Scopus
2-s2.0-85180342514