Accurate estimation of damping effects in salient pole synchronous machines is essential for improved modeling and stability analysis. Although the application of the Standstill Frequency Response (SSFR) method to machines without damper windings has been discussed in previous studies, this work focuses on demonstrating its practical applicability using a Voltage Source Inverter (VSI) with a sine filter to ensure highquality excitation signals. The objective is to evaluate whether SSFR can effectively capture damping phenomena arising from eddy currents and magnetic saturation in the pole structure, even in the absence of explicit damper bars. Experimental tests are carried out under controlled standstill conditions, and the resulting frequency responses are analyzed to identify dampingrelated characteristics. The results confirm that, with proper excitation and measurement setup, the SSFR method remains valid for such machines. This study contributes by validating a practical, inverter-based approach for SSFR testing, offering enhanced precision and applicability in modern synchronous machine analysis.
Název v anglickém jazyce
Estimation of Damping Effects in a Salient Pole Synchronous Machine without a Damper Using SSFR Testing with a VSI
Popis výsledku anglicky
Accurate estimation of damping effects in salient pole synchronous machines is essential for improved modeling and stability analysis. Although the application of the Standstill Frequency Response (SSFR) method to machines without damper windings has been discussed in previous studies, this work focuses on demonstrating its practical applicability using a Voltage Source Inverter (VSI) with a sine filter to ensure highquality excitation signals. The objective is to evaluate whether SSFR can effectively capture damping phenomena arising from eddy currents and magnetic saturation in the pole structure, even in the absence of explicit damper bars. Experimental tests are carried out under controlled standstill conditions, and the resulting frequency responses are analyzed to identify dampingrelated characteristics. The results confirm that, with proper excitation and measurement setup, the SSFR method remains valid for such machines. This study contributes by validating a practical, inverter-based approach for SSFR testing, offering enhanced precision and applicability in modern synchronous machine analysis.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2025 International Conference on Applied Electronics (AE)
ISBN
979-8-3315-3647-3
ISSN
1803-7232
e-ISSN
1805-9597
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Pilsen, Czech Republic
Datum konání akce
8. 9. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—