Surface density of dermo-epidermal lamellae and mechanical testing of suspensory apparatus of equine hoof
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23520%2F10%3A00503859" target="_blank" >RIV/49777513:23520/10:00503859 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Surface density of dermo-epidermal lamellae and mechanical testing of suspensory apparatus of equine hoof
Popis výsledku v původním jazyce
The corio-epidermal junction (CEJ) of equine hoof is suspensory apparatus between the wall of the hoof and the distal phalanx. We assessed the surface density of lamellae of CEJ as well as mechanical behavior of suspensory apparatus. We also concentratedon creation of 3D reconstruction of the equine hoof included wall horn, pars inflexa, digital cushion, solea, ligaments, tendons, frog, navicular bone, distal phalanx and corium. The mechanical properties of frozen and of formalin-fixed tissue samples were determined using uniaxial tensile tests. The surface density of the primary (PL) and secondary (SL) lamellae of CEJ was estimated using the 3D reconstruction and using stereological method employing the testing probe of circular arcs. Morphological results showed that the surface density of the SL was higher in the epidermal region than in the dermal region. Mechanical results showed that moduli of elasticity in fixed samples were stiffer by one order than in frozen sampl es.
Název v anglickém jazyce
Surface density of dermo-epidermal lamellae and mechanical testing of suspensory apparatus of equine hoof
Popis výsledku anglicky
The corio-epidermal junction (CEJ) of equine hoof is suspensory apparatus between the wall of the hoof and the distal phalanx. We assessed the surface density of lamellae of CEJ as well as mechanical behavior of suspensory apparatus. We also concentratedon creation of 3D reconstruction of the equine hoof included wall horn, pars inflexa, digital cushion, solea, ligaments, tendons, frog, navicular bone, distal phalanx and corium. The mechanical properties of frozen and of formalin-fixed tissue samples were determined using uniaxial tensile tests. The surface density of the primary (PL) and secondary (SL) lamellae of CEJ was estimated using the 3D reconstruction and using stereological method employing the testing probe of circular arcs. Morphological results showed that the surface density of the SL was higher in the epidermal region than in the dermal region. Mechanical results showed that moduli of elasticity in fixed samples were stiffer by one order than in frozen sampl es.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Plzeňský lékařský sborník (Pilsen Medical Report)
ISSN
0551-1038
e-ISSN
—
Svazek periodika
Neuveden
Číslo periodika v rámci svazku
Suppl. 82
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—