On-line Ampacity Monitoring from Phasor Measurements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23520%2F14%3A43923255" target="_blank" >RIV/49777513:23520/14:43923255 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.3182/20140824-6-ZA-1003.02592" target="_blank" >http://dx.doi.org/10.3182/20140824-6-ZA-1003.02592</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3182/20140824-6-ZA-1003.02592" target="_blank" >10.3182/20140824-6-ZA-1003.02592</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On-line Ampacity Monitoring from Phasor Measurements
Popis výsledku v původním jazyce
The knowledge of transmission line parameters involving series impedance and shunt admittance is crucial to power system analysis and power system state estimation. Particularly in areas of power systems protection it is critical to have accurate valuesof these parameters to determine the line ampacity. The line parameters change according to the load level and weather conditions, so it is necessary to identify the line parameters in real time. The paper deals with the on-line parameter identificationof transmission lines from synchronized measurements of current and voltage phasors provided by the phasor measurement units. The series and shunt line parameters are recursively estimated from the phasor measurements and weather conditions using the extended Kalman filter. Contrary to the other works, an actual line temperature and reference resistance are estimated, which makes possible to monitor the actual state of the transmission line in order to determine an actual reserve or pred
Název v anglickém jazyce
On-line Ampacity Monitoring from Phasor Measurements
Popis výsledku anglicky
The knowledge of transmission line parameters involving series impedance and shunt admittance is crucial to power system analysis and power system state estimation. Particularly in areas of power systems protection it is critical to have accurate valuesof these parameters to determine the line ampacity. The line parameters change according to the load level and weather conditions, so it is necessary to identify the line parameters in real time. The paper deals with the on-line parameter identificationof transmission lines from synchronized measurements of current and voltage phasors provided by the phasor measurement units. The series and shunt line parameters are recursively estimated from the phasor measurements and weather conditions using the extended Kalman filter. Contrary to the other works, an actual line temperature and reference resistance are estimated, which makes possible to monitor the actual state of the transmission line in order to determine an actual reserve or pred
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED1.1.00%2F02.0090" target="_blank" >ED1.1.00/02.0090: NTIS - Nové technologie pro informační společnost</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFAC Proceedings Volumes (IFAC-PapersOnline)
ISBN
978-3-902823-62-5
ISSN
1474-6670
e-ISSN
—
Počet stran výsledku
6
Strana od-do
3164-3169
Název nakladatele
Elsevier
Místo vydání
Amsterdam
Místo konání akce
Cape Town, South Africa
Datum konání akce
24. 8. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—