Computational and experimental modelling of unstable pelvic fractures
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23520%2F24%3A43973532" target="_blank" >RIV/49777513:23520/24:43973532 - isvavai.cz</a>
Výsledek na webu
<a href="http://hdl.handle.net/11025/57846" target="_blank" >http://hdl.handle.net/11025/57846</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Computational and experimental modelling of unstable pelvic fractures
Popis výsledku v původním jazyce
The finite element model of male pelvis which reflects the composite bone structure is developed. Both cortical and trabecular bone geometry are based on CT scans of the commercially available synthetic model of pelvis which is further applied within an experimental biomechanical study focusing on stability of selected minimally invasive fixation techniques. Results of the experimental measurements are utilised for verification of the computational model. In order to assess the robustness of the validated computational model, the computational study is extended for a geometrically different male pelvis based on CT scans of a real patient. Consistency of the achieved results is presented.
Název v anglickém jazyce
Computational and experimental modelling of unstable pelvic fractures
Popis výsledku anglicky
The finite element model of male pelvis which reflects the composite bone structure is developed. Both cortical and trabecular bone geometry are based on CT scans of the commercially available synthetic model of pelvis which is further applied within an experimental biomechanical study focusing on stability of selected minimally invasive fixation techniques. Results of the experimental measurements are utilised for verification of the computational model. In order to assess the robustness of the validated computational model, the computational study is extended for a geometrically different male pelvis based on CT scans of a real patient. Consistency of the achieved results is presented.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
<a href="/cs/project/EF17_048%2F0007280" target="_blank" >EF17_048/0007280: Aplikace moderních technologií v medicíně a průmyslu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů