Musculoskeletal computer model used for gait analysis of patients with total endoprosthesis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23640%2F14%3A43924320" target="_blank" >RIV/49777513:23640/14:43924320 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Musculoskeletal computer model used for gait analysis of patients with total endoprosthesis
Popis výsledku v původním jazyce
The number of patients with total endoprosthesis is still increasing. This problem often causes movement restriction and subsequently complications with integration into society. Thus some suitable modern treatments and rehabilitations are essential fortheir efficient help. The aim of work is to reconstruct the real recorded motions of orthopaedic patients and to perform mechanical analysis of human body. Kinematic data for patients are measured using the opto-electrical capture system called Vicon. The subjects are asked to perform slow walking. Obtained motion capture data are used to drive the adapted computer human body model available within the open repository of AnyBody Modeling System. The model is based on an inverse dynamic analysis and an optimization algorithm for muscle recruitment. Gait analysis is performed, i.e. muscle and joint reaction forces, muscle activation as well as muscle moment arms are computed. Obtained results contribute to faster diagnosis, optimize rehab
Název v anglickém jazyce
Musculoskeletal computer model used for gait analysis of patients with total endoprosthesis
Popis výsledku anglicky
The number of patients with total endoprosthesis is still increasing. This problem often causes movement restriction and subsequently complications with integration into society. Thus some suitable modern treatments and rehabilitations are essential fortheir efficient help. The aim of work is to reconstruct the real recorded motions of orthopaedic patients and to perform mechanical analysis of human body. Kinematic data for patients are measured using the opto-electrical capture system called Vicon. The subjects are asked to perform slow walking. Obtained motion capture data are used to drive the adapted computer human body model available within the open repository of AnyBody Modeling System. The model is based on an inverse dynamic analysis and an optimization algorithm for muscle recruitment. Gait analysis is performed, i.e. muscle and joint reaction forces, muscle activation as well as muscle moment arms are computed. Obtained results contribute to faster diagnosis, optimize rehab
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů